Reproducibility of sterilized rubber impressions.
نویسندگان
چکیده
Impressions, dentures and other dental appliances may be contaminated with oral micro-flora or other organisms of varying pathogenicity from patient's saliva and blood. Several approaches have been tried to control the transmission of infectious organisms via dental impressions and because disinfection is less effective and has several drawbacks for impression characterization, several sterilization methods have been suggested. This study evaluated the reproducibility of rubber impressions after sterilization by different methods. Dimensional accuracy and wettability of two rubber impression materials (vinyl polysiloxane and polyether) were evaluated after sterilization by each of three well-known methods (immersion in 2% glutaraldehyde for 10 h, autoclaving and microwave radiation). Non-sterilized impressions served as control. The effect of the tray material on impression accuracy and the effect of topical surfactant on the wettability were also evaluated. One-way ANOVA with Dunnett's method was used for statistical analysis. All sterilizing methods reduced the reproducibility of rubber impressions, although not always significantly. Microwave sterilization had a small effect on both accuracy and wettability. The greater effects of the other methods could usually be overcome by using ceramic trays and by spraying impression surfaces with surfactant before pouring the gypsum mix. There was one exception: glutaraldehyde still degraded dimensional accuracy even with ceramic trays and surfactant. We conclude that a) sterilization of rubber impressions made on acrylic trays was usually associated with a degree of dimensional change; b) microwave energy seems to be a suitable technique for sterilizing rubber impressions; c) topical surfactant application helped restore wettability of sterilized impressions.
منابع مشابه
Butyl rubber stoppers increase the shelf life of prereduced, anaerobically sterilized media.
Butyl rubber stoppers as compared with neoprene or black rubber stoppers significantly increased the shelf life of prereduced, anaerobically sterilized media for growth of obligately anaerobic bacteria.
متن کاملSurface reproducibility of resin die materials with various impression materials.
Surface reproduction was evaluated for epoxy resin and polyether resin dies as well as for gypsum dies by observing the changes in roughness. Significant differences were found by the interaction of the impression and the dies. The resin dies generally showed better results than the gypsum dies when the elastomeric impressions were used. Especially the resin dies were both excellent in surface ...
متن کاملWhite light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions
PURPOSE The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. MATERIALS AND METHODS Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D s...
متن کاملRepeatability and reproducibility of individual abutment impression, assessed with a blue light scanner
PURPOSE We assessed the repeatability and reproducibility of abutment teeth dental impressions, digitized with a blue light scanner, by comparing the discrepancies in repeatability and reproducibility values for different types of abutment teeth. MATERIALS AND METHODS To evaluate repeatability, impressions of the canine, first premolar, and first molar, prepared for ceramic crowns, were repea...
متن کاملAn evaluation of the fit of metal-ceramic restorations made with an autoclaved silicone-based impression material.
AIM To demonstrate the clinical feasibility of autoclaving certain silicone impression materials in order to avoid potential cross-contamination during handling, transport, and subsequent processing. BACKGROUND Semicritical devices are recommended to be treated at least with high-level disinfectants or actually steam sterilized at 134°C. To date dental impressions have been disinfected rather...