The additive value of three-dimensional derived left atrial volume and carotid imaging in dobutamine stress echocardiography.

نویسندگان

  • Vasileios Sachpekidis
  • Amit Bhan
  • Matthias Paul
  • Silvia Gianstefani
  • Lindsay Smith
  • Joseph Reiken
  • Nicola Walker
  • Derek Harries
  • Peter Pearson
  • Mark J Monaghan
چکیده

AIMS to evaluate whether the three-dimensional (3D) left atrial volume index (LAVI) and/or the presence of carotid plaques (CP) can predict the result of dobutamine stress echocardiography (DSE), thereby aiding interpretation. METHODS AND RESULTS we studied 130 patients (52 male, mean age 63 ± 11 years) with normal resting wall motion (WM) undergoing DSE. All patients had the end-systolic 2D and 3D LAVI measured, as well as bilateral carotid scanning. DSE was reported as abnormal in 50 (38.5%) patients. 3D end-systolic LAVI measurements were significantly higher (31.5 ± 8.2 vs 27.4 ± 7.4 mL/m(2), P = 0.004) in those with an abnormal DSE. The two groups did not differ significantly on the 2D derived maximum LAVI measurements (36.2 ± 9.5 vs 34.2 ± 11.2, P = 0.299) and the presence of plaques in the carotid arteries (89.1 vs. 76.2%, P = 0.100). Receiver operating characteristic curves were created to define cut-offs that could predict the DSE result for the 3D LAVI. A 3D LAVI of >24.5 mL/m(2) had a sensitivity of 80% for predicting an abnormal DSE, whereas a value of >36.0 mL/m(2) had a specificity of 93% for the same cause. Intra-observer (r = 0.997, P < 0.0001) and inter-observer (r = 0.961, P < 0.0001) variability for 3D LAVI measurements was found to be excellent. CONCLUSION three-dimensional (but not 2D) assessment of LAVI may offer additional information in predicting the result of DSE. Carotid scanning did not offer additional information for the same cause.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary Artery Spasm During Dobutamine Stress Echocardiography: A Case Report

Dobutamine stress echocardiography (DSE) has been widely used as a diagnostic and prognostic modality in the management of stress. DSE is associated with limited complications and adverse effects on the health of patients. In this case report, we described a 42-year-old female patient with dobutamine-induced coronary artery spasm with history of exertional dyspnea, which had deteriorated recent...

متن کامل

Left atrial volume assessed by transthoracic three dimensional echocardiography and magnetic resonance imaging: dynamic changes during the heart cycle in children.

OBJECTIVE To assess the dynamic changes in left atrial volume by transthoracic three dimensional echocardiography and compare the results with those obtained by magnetic resonance imaging (MRI). DESIGN AND PATIENTS 30 healthy children (15 boys and 15 girls, aged 8 to 13 years) underwent examination by three dimensional echocardiography and MRI. METHODS Three dimensional echocardiography of ...

متن کامل

Predictive value of normal left atrial volume in stress echocardiography.

OBJECTIVES Our objective was to evaluate whether normal left atrial volume index (LAVI) is a predictor of a normal stress echocardiogram and thus a predictor of low ischemic risk. BACKGROUND Left atrial enlargement is closely related to the chronicity and intensity of the burden of increased ventricular filling pressure. Typically ischemic heart disease (IHD) has a long period of subclinical ...

متن کامل

A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures

Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...

متن کامل

Analysis of the left atrial appendage by three-dimensional transesophageal echocardiography.

This study was designed to determine the ability and reliability of 3-dimensional (3D) transesophageal echocardiography (TEE) to assess the geometry and size of the left atrial appendage (LAA). Three-dimensional TEE may allow more accurate assessment of, and provide additional information on, LAA morphology compared to 2-dimensional TEE. Validation studies for LAA morphology data derived from 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 12 1  شماره 

صفحات  -

تاریخ انتشار 2011