Renal Water Molecular Diffusion Characteristics in Healthy Native Kidneys: Assessment with Diffusion Tensor MR Imaging

نویسندگان

  • Zhenfeng Zheng
  • Huilan Shi
  • Jing Zhang
  • Yunting Zhang
چکیده

BACKGROUND To explore the characteristics of diffusion tensor imaging (DTI) and magnetic resonance (MR) imaging in healthy native kidneys. METHODS Seventy-three patients without chronic kidney disease underwent DTI-MRI with spin echo-echo planar (SE-EPI) sequences accompanied by an array spatial sensitivity encoding technique (ASSET). Cortical and medullary mean, axial and radial diffusivity (MD, AD and RD), fractional anisotropy (FA) and primary, secondary and tertiary eigenvalues (λ1, λ2, λ3) were analysed in both kidneys and in different genders. RESULTS Cortical MD, λ2, λ3, and RD values were higher than corresponding medullary values. The cortical FA value was lower than the medullary FA value. Medullary λ1 and RD values in the left kidney were lower than in the right kidney. Medullary λ2, and λ3 values in women were higher than those in men. Medullary FA values in women were lower than those in men. Medullary FA (r = 0.351, P = 0.002) and λ1 (r = 0.277, P = 0.018) positively correlated with eGFR. Medullary FA (r = -0.25, P = 0.033) negatively correlated with age. CONCLUSIONS Renal water molecular diffusion differences exist in human kidneys and genders. Age and eGFR correlate with medullary FA and primary eigenvalue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion Tensor Imaging of the Kidneys: Influence of b-Value and Number of Encoding Directions on Image Quality and Diffusion Tensor Parameters

OBJECTIVES The purpose of this study was to evaluate to which degree investment of acquisition time in more encoding directions leads to better image quality (IQ) and what influence the number of encoding directions and the choice of b-values have on renal diffusion tensor imaging (DTI) parameters. MATERIAL AND METHODS Eight healthy volunteers (32.3 y ± 5.1 y) consented to an examination in a...

متن کامل

Loss of renal diffusion anisotropy in Patients with Chronic Kidney Disease

Introduction: The measurement of the diffusion characteristics of the kidney could provide useful insights into the mechanisms of various renal diseases. The anisotropic diffusion properties in the kidneys is a result of structures like vessels, tubules and collecting ducts, which are oriented in a radial fashion. Diffusion tensor imaging (DTI) is a MR imaging technique that can be used to char...

متن کامل

Dynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors

Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...

متن کامل

An Introduction to Visualization of Diffusion Tensor Imaging and its Applications

Water diffusion is anisotropic in organized tissues such as white matter and muscle. Diffusion tensor imaging (DTI), a non-invasive MR technique, measures water self-diffusion rates and thus gives an indication of the underlying microstructure of tissue. The diffusion rate is often expressed by a second-order tensor. Visualizing DTI in an insightful way is challenging because of the high dimens...

متن کامل

Diffusion-Weighted Magnetic Resonance Imaging Findings of Kidneys with Obstructive Uropathy: Differentiation between Benign and Malignant Etiology

PURPOSE In this study, we aimed to evaluate the capability of diffusion-weighted magnetic resonance imaging (DWI) in differentiation between benign and malignant etiology of obstructive uropathy. MATERIALS AND METHODS DWI was performed in 41 patients with hydronephrotic kidneys and 26 healthy volunteers. MR imaging was performed using a 1.5 T whole-body superconducting MR scanner. The signal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014