Calibration of Low Density EEG Sensor Arrays for Brain Source Localization
نویسندگان
چکیده
This paper investigates the performance of calibration techniques on synthetic Electroencephalography (EEG) data. Brain source localization was performed using an iterative algorithm. A transfer-function-based calibration technique was developed. This technique can be applied in two forms: external calibration and autocalibration. For a low density EEG array system, it was shown that the proposed calibration technique can offer improved performance relative to previously published work.
منابع مشابه
Multimodal Spatial Calibration for Accurately Registering EEG Sensor Positions
This paper proposes a fast and accurate calibration method to calibrate multiple multimodal sensors using a novel photogrammetry system for fast localization of EEG sensors. The EEG sensors are placed on human head and multimodal sensors are installed around the head to simultaneously obtain all EEG sensor positions. A multiple views' calibration process is implemented to obtain the transformat...
متن کاملSuccessive Estimation Method of Locating Dipoles based on QR Decomposition using EEG Arrays Successive Estimation Method of Locating Dipoles based on QR Decomposition using EEG Arrays
EEG is a noninvasive technique useful for the human brain mapping and for the estimation of neural electrical activities in human brain. A goal of processing EEG signals of a subject is the localization of neural current sources in human brain known as dipoles. Although this location estimation problem can be modeled as a particular kind of parameter estimation problem as in array signal proces...
متن کاملEEG source localization: Sensor density and head surface coverage
BACKGROUND The accuracy of EEG source localization depends on a sufficient sampling of the surface potential field, an accurate conducting volume estimation (head model), and a suitable and well-understood inverse technique. The goal of the present study is to examine the effect of sampling density and coverage on the ability to accurately localize sources, using common linear inverse weight te...
متن کاملA New Approach to Self-Localization for Mobile Robots Using Sensor Data Fusion
This paper proposes a new approach for calibration of dead reckoning process. Using the well-known UMBmark (University of Michigan Benchmark) is not sufficient for a desirable calibration of dead reckoning. Besides, existing calibration methods usually require explicit measurement of actual motion of the robot. Some recent methods use the smart encoder trailer or long range finder sensors such ...
متن کاملEvaluation of Spatial Resolution and Noise Sensitivity of sLORETA Method for EEG Source Localization Using Low-Density Headsets
Electroencephalography (EEG) has enjoyed considerable attention over the past century and has been applied for diagnosis of epilepsy, stroke, traumatic brain injury and other disorders where 3D localization of electrical activity in the brain is potentially of great diagnostic value. In this study we evaluate the precision and accuracy of spatial localization of electrical activity in the brain...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012