Improved R2* measurement accuracy with absolute SNR truncation and optimal coil combination.

نویسندگان

  • Xiaoming Yin
  • Saurabh Shah
  • Aggelos K Katsaggelos
  • Andrew C Larson
چکیده

Accurate R2* measurements are critical for many abdominal imaging applications. Conventionally, R2* maps are derived via the monoexponential fitting of signal decay within a series of gradient-echo (GRE) images reconstructed from multichannel datasets combined using a root sum-of-squares (RSS) approach. However, the noise bias at low-SNR TEs from RSS-reconstructed data often causes the underestimation of R2* values. In phantom, ex vivo animal model and normal volunteer studies, we investigated the accuracy of low-SNR R2* measurement when combining truncation and coil combination methods. The accuracy for R2* estimations was shown to be affected by the intrinsic R2* value, SNR level and the chosen reconstruction method. The R2* estimation error was found to decrease with increasing SNR level, decreasing R2* value and the use of the optimal B1-weighted combined (OBC) image reconstruction method. Data truncation based on rigorous voxel-wise SNR estimates can reduce R2* measurement error in the setting of low SNR with fast signal decay. When optimal SNR truncation thresholds are unknown, the OBC method can provide optimal R2* measurements given the minimal truncation requirements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

R2* Measurement Using Absolute SNR-Weighted Least Square Regression

INTRODUCTION Accurate R2* measurements are critical for many quantitative imaging applications. R2* is estimated via mono-exponential fitting of signal decay within a series of gradient echo (GRE) images sampled at increasing TE. Root-sum-of-square (RSS) remains the most common approach to combine surface coil array images at each TE prior to the data fitting procedure. Rapid signal decay can r...

متن کامل

Automatic Coil Selection for SENSE Imaging with Large Coil Arrays

Introduction Parallel imaging using coil arrays with large number of receive elements allows improved imaging performance and increased SNR [1, 2]. However, the use of a large number of coil elements can lead to memory storage problems and to increased reconstruction times. Several techniques for data reduction were presented, realized either by linear combination of the original coil data or b...

متن کامل

Combination of Phased-Array Coil Signals in Localized 2D Correlated Spectroscopy: Artifacts and Remedies

Introduction & Purpose: Multi-channel phased-array radio-frequency (RF) coils are capable of acquiring several streams of acquisitions in parallel, resulting in improved signal-to-noise ratios (SNR) and faster scan times (1,2). Data streams from these coils must be added in-phase during coil combination or risk losing signal to phase cancellation. Conventional coil combination schemes work well...

متن کامل

Coil combination of multichannel MRSI data at 7 T: MUSICAL

The goal of this study was to evaluate a new method of combining multi-channel (1)H MRSI data by direct use of a matching imaging scan as a reference, rather than computing sensitivity maps. Seven healthy volunteers were measured on a 7-T MR scanner using a head coil with a 32-channel array coil for receive-only and a volume coil for receive/transmit. The accuracy of prediction of the phase of ...

متن کامل

Improved cine displacement-encoded MRI using balanced steady-state free precession and time-adaptive sensitivity encoding parallel imaging at 3 T.

Cine displacement-encoded MRI is a promising modality for quantifying regional myocardial function. However, it has two major limitations: low signal-to-noise ratio (SNR) and data acquisition efficiency. The purpose of this study was to incrementally improve the SNR and the data acquisition efficiency of cine displacement-encoded MRI through the combined use of balanced steady-state free preces...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NMR in biomedicine

دوره 23 10  شماره 

صفحات  -

تاریخ انتشار 2010