Amplification of ultrashort pulses in krypton fluoride at 248 nm.
نویسندگان
چکیده
Ultrashort pulses were produced at 248 nm by using a transverse-discharge KrF* excimer laser as a high-energy amplifier system. Input pulses for the amplifier system were obtained by upconverting the output of a modelocked visible dye laser to the ultraviolet by using nonlinear crystals. Pulses of up to 20 mJ; in energy with 10-30-psec duration were obtained at 10 pulses/sec. The output pulse width was characterized by using an electronic autocorrelator.
منابع مشابه
Generation of 35.5-nm coherent radiation.
Tunable coherent radiation was produced at 35.5 nm by seventh-harmonic conversion of 248-nm radiation from a krypton fluoride excimer laser. The nonlinear interaction took place at the intersection of the laser focus and a pulsed, supersonic helium gas jet. Third- and fifth-harmonic generation produced coherent outputs at 83 and 50 nm in both helium and xenon gas jets.
متن کاملHigh-power parametric amplification of 11.8-fs laser pulses with carrier-envelope phase control.
Phase-stable parametric chirped-pulse amplification of ultrashort pulses from a carrier-envelope phase-stabilized mode-locked Ti:sapphire oscillator (11.0 fs) to 0.25 mJ/pulse at 1 kHz is demonstrated. Compression with a grating compressor and a LCD shaper yields near-Fourier-limited 11.8-fs pulses with an energy of 0.12 mJ. The amplifier is pumped by 532-nm pulses from a synchronized mode-lock...
متن کاملUltrashort optical-vortex pulse generation in few-cycle regime.
We generated a 2.3-cycle, 5.9-fs, 56-μJ ultrashort optical-vortex pulse (ranging from ~650 to ~950 nm) in few-cycle regime, by optical parametric amplification. It was performed even by using passive elements (a pair of prisms and chirped mirrors) for chirp compensation. Spectrally-resolved interferograms and intensity profiles showed that the obtained pulses have no spatial or topological-char...
متن کاملExcimer laser-induced simultaneous ablation and spectral identification of normal and atherosclerotic arterial tissue layers.
A krypton-fluorine excimer laser at a 248-nm wavelength was used to irradiate normal and severely atherosclerotic segments of human postmortem femoral arteries. Single pulses and multiple pulses required for penetration or perforation of the arterial wall were applied with 16 nsec pulse width and 5 J/cm2/pulse energy fluence. The total fluorescence of irradiated and ablated tissue was analyzed ...
متن کاملGeneration of high-brightness coherent radiation in the vacuum ultraviolet by four-wave parametric oscillation in mercury vapor.
Coherent radiation at several wavelengths in the vacuum ultraviolet (VUV) has been generated by four-wave parametric oscillation in mercury vapor. When a powerful ultraviolet pump laser of frequency omega(p) is tuned to a two-photon resonance, VUV signal photons at frequency omega(s), as well as idler photons at frequency omega(i), are generated such that omega(s) + omega(i) = 2omega(p). A freq...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 7 9 شماره
صفحات -
تاریخ انتشار 1982