Interrupting gel layer between Double cuffs prevents fluid leakage past tracheal tube cuffs.

نویسندگان

  • J Y Hwang
  • S H Han
  • S H Park
  • S J Park
  • S Park
  • S H Oh
  • J H Kim
چکیده

BACKGROUND Current tracheal tubes (TTs) cannot guarantee a perfect seal against pulmonary aspiration of upper airway secretions. The purpose of this study was to investigate whether a gel layer between the tracheal tube with double cuffs (Double cuffs) prevents fluid leakage past TT cuffs. METHODS In vitro fluid leakage tests were performed using the Double cuff with or without a gel layer between the two cuffs and four commercially available TTs (Euromedical Standard TT, Mallinckrodt Hi-Lo™, Microcuff, and Mallinckrodt TaperGuard™) when placed in artificial tracheas with three-different internal diameters (ID; 16, 20, and 22 mm). Blue-dyed water (5 ml) was placed above the cuff, and the extent of fluid leakage was observed for 48 h. Each test was repeated five times with new tubes at six different intracuff pressures (15, 20, 25, 30, 40, and 50 cm H2O). RESULTS In all of the conventional TTs and the Double cuff without a gel layer, fluid leakage was observed even at clinically acceptable intracuff pressures (25-30 cm H2O). However, in the Double cuff with a gel layer, no fluid leakage was observed for 48 h at all intracuff pressures in three-different sized artificial tracheas. At an intracuff pressure of 20 cm H2O in a 20 mm ID trachea, the average volume of injected gel was 2.0 ml. After removal of the TT, the mean volume of the remaining gel in the trachea was 0.10 ml. CONCLUSIONS A prototype TT with gel-layered Double cuffs completely blocked fluid leakage past the cuffs for 48 h in a bench-top model. Clinical studies are required to determine whether this TT reduces the risk of ventilator-associated pneumonia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RESPIRATION AND THE AIRWAY Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study

Key points † Optimizing tracheal sealing is of clinical interest: fluid leakage past the tube cuff plays an important role in the pathogenesis of VAP. † Tapered shaped tube cuff offering a sealing zone with reduced folds and channels is a new strategy to minimize fluid leakage past the tracheal tube cuff. † Tracheal tube cuffs made from PVC show much more and faster fluid leakage than cuffs mad...

متن کامل

Leakage of fluid around endotracheal tube cuffs: a cadaver study

BACKGROUND The aim of the study was to evaluate the leakage of liquid past the cuffs of tracheal tubes in fresh frozen human heads. METHODS Six truncated fresh frozen heads were used and intubated with 8.0 mm endotracheal tubes. The intracuff pressures tested were 30 and 100 cmH2O. Subsequently, 20 ml of each of two oral antiseptic rinses (0.2% chlorhexidine and octenidine [octenidol®, Schülk...

متن کامل

Comparison of microaspiration around TaperGuard tube cuffs and standard tracheal tubes in obese patients subjected to surgery under general anesthesia.

UNLABELLED Tracheal secretion leakage might lead to ventilator-associated pneumonia. Standard tracheal tube cuffs are cylindrical in shape. Bronchial tree aspiration is observed in the presence of leakage past tracheal tube cuffs. The new TaperGuard tracheal tube has a cuff in the shape of a cone, preventing from the development of microtubules and microaspiration. The aim of the study was to c...

متن کامل

Gel lubrication of the tracheal tube cuff reduces pulmonary aspiration.

BACKGROUND Leakage of fluid occurs along the longitudinal folds within the wall of an inflated high-volume, low-pressure cuff. Theoretically, lubrication of the cuff with a water-soluble gel might prevent aspiration by plugging the channels in the cuff wall. Pulmonary aspiration during anesthesia has been linked with postoperative pneumonia and during critical illness causes ventilator-associat...

متن کامل

The effect of tracheal tube size on air leak around the cuffs

BACKGROUND This randomized single-blinded, cross-over study was done to evaluate the influence of the size of tracheal tubes on air leaks around the cuffs. METHODS In a benchtop model, the number of longitudinal folds on the cuffs was evaluated for different sizes of tracheal tubes. In an anesthetized patient study, thirty patients scheduled for elective surgery under general anesthesia were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 111 3  شماره 

صفحات  -

تاریخ انتشار 2013