An improved reconstruction procedure for the correction of local magnification effects in 3DAP

نویسنده

  • F. De Geuser
چکیده

A new 3DAP reconstruction procedure is proposed, which accounts for the evaporation field of a secondary phase. It applies the existing cluster selection softwares to identify the atoms of the second phase and subsequently an iterative algorithm to homogenise the volume laterally. This procedure, easily implementable on existing reconstruction software, has been applied successfully on simulated and real 3DAP analyses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An improved reconstruction procedure for the correction of local magnification effects in three-dimensional atom-probe

A new 3DAP reconstruction procedure is proposed, which accounts for the evaporation field of a secondary phase. It applies the existing cluster selection softwares to identify the atoms of the second phase and subsequently an iterative algorithm to homogenise the volume laterally. This procedure, easily implementable on existing reconstruction software, has been applied successfully on simulate...

متن کامل

Attenuation Correction in SPECT during Image Reconstruction using an Inverse Monte Carlo Method: A Simulation Study

Introduction: The main goal of SPECT imaging is to determine activity distribution inside the organs of the body. However, due to photon attenuation, it is almost impossible to do a quantitative study. In this paper, we suggest a mathematical relationship between activity distribution and its corresponding projections using a transfer matrix. Monte Carlo simulation was used to find a precise tr...

متن کامل

Palate Mucoperosteum: An Usefull Adjunct in Buccal Mucosa Reconstruction

Background: Palate is a complex structure separating oro- and nasopharynx. However, reconstruction of the defects of palate is much simpler because of the versatile mucoperiosteal flaps. Here, we present our experience of palatal mucoperiosteal flap used in different situations. Methods: Fifteen patients of palatal as well as buccal mucosa defects were reconstructed using either free or pedicl...

متن کامل

Evaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom

Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...

متن کامل

A New Approach for Scatter Removal and Attenuation Compensation from SPECT/CT Images

  Objective(s): In SPECT, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. Many techniques for attenuation and scatter correction have been proposed. An acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. Here, we propose new Maximum Likelihood Expectation Maximiz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004