High-resolution tweezers for cutting and coagulation reprocessing.

نویسندگان

  • Bruno Zilberstein
  • R C R Silva
  • S G Valim
  • K T H Yukui
  • R Valentim
چکیده

INTRODUCTION Several studies have demonstrated the clinical benefits of the use of high resolution instruments in surgery, with reduction in the operative time, easy handling and effectiveness in the incisions, as well as lower smoke generation and thermal tissue damage. AIM To demonstrate the technical feasibility of reusing devices of high resolution for cutting and coagulation, theoretically recommended for single use. METHOD Was evaluated the efficacy of cleaning, sterilization process and functional quality of the material. The process was applied in four tweezers brand Ligasure - Valleylab. Each was identified with ribbons of different colors autoclavable for tracking. Two were submitted directly to the cleaning after the first use and from the other two were collected samples of this cleaning for the first culture. All tweezers passed through the cleaning process prior to sterilization. Then were sterilized in hydrogen peroxide. After the sterilization process, was taken material from the devices and put it on saline solution for culture. After, the tweezers were tested by a surgeon to analyze its performance in a sample of beef. Randomly at each test the researcher contaminated tweezers with strains of Pseudomonas aeruginosa, Staphylococcus aureus and Candida albicans. This process was repeated four times. The material was sent to the laboratory and seeded in culture medium capable of microbiological identification. For quality control tests all biological, chemical and quality certification of products used in the process were attached. RESULTS The results of all cultures were negative, and functionality was preserved in the four reuses. CONCLUSION As to the functionality, the tweezers may be used at least four times, the number of times tested in this experiment. Therefore, it can be used for five times, the first coming from the factory and four more after reprocessing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wastewater Treatment of Stone Cutting Industries by Coagulation Process

Background & Aims of the Study: The wastewater created as a result of stone cutting industries enters some pools for re-consumption so that its suspended solids settle by gravity. By taking to account the high volume of water and sludge, treatment of wastewater and removal of sludge cause many problems for stone cutting units. The objective of this study was to determine the quality of wast...

متن کامل

Reprocessing of Sangan iron ore tailings by flotation

The Sangan processing plant consists of four consecutive low-intensity magnetic separation steps with the same magnetic field intensity of 1300 Gauss for upgradation of iron ore. Hence, the iron ore minerals with lower magnetic susceptibility or interlocked with gangue minerals have no opportunity for upgradation, and proceed to the tailing dam. Flotation is a powerful technique for upgradation...

متن کامل

High-Resolution Optical Tweezers for Single-Molecule Manipulation

Forces hold everything together and determine its structure and dynamics. In particular, tiny forces of 1-100 piconewtons govern the structures and dynamics of biomacromolecules. These forces enable folding, assembly, conformational fluctuations, or directional movements of biomacromolecules over sub-nanometer to micron distances. Optical tweezers have become a revolutionary tool to probe the f...

متن کامل

Cessation of deliberate self harm following eye movement desensitisation and reprocessing: A case report

We present a case report of an eighteen year old female patient presenting with a psychological trauma related complaint. Part of the manifestation of the complaint included acts of self cutting over a number of years. Following two sessions of Eye Movement Desensitization & Reprocessing with one of the authors (DM) her self cutting ceased. This is maintained at thirteen months follow up. We co...

متن کامل

measuring viscoelastic properties of Red Blood Cell using optical tweezers

Efforts have been made to study the behavior of complex materials in micrometer dimensions with various techniques. One of these methods is the use of optical tweezers for biophysical applications. Red blood cells, as the most abundant blood-forming cells, play an important role in the life of living organisms, and their unique mechanical properties are important. In this report, the study of s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Arquivos brasileiros de cirurgia digestiva : ABCD = Brazilian archives of digestive surgery

دوره 26 3  شماره 

صفحات  -

تاریخ انتشار 2013