Evaluation of a commercially‐available block for spatially fractionated radiation therapy

نویسندگان

  • Courtney Buckey
  • Sotirios Stathakis
  • Ken Cashon
  • Alonso Gutierrez
  • Carlos Esquivel
  • Chengyu Shi
  • Nikos Papanikolaou
چکیده

In this paper, we present the dosimetric characteristics of a commercially-produced universal GRID block for spatially fractioned radiation therapy. The dosimetric properties of the GRID block were evaluated. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a solid water phantom to determine the relative output of the GRID block as well as its spatial dosimetric characteristics. The surface dose under the block and at the openings was measured using ultra thin TLDs. After introducing the GRID block into the treatment planning system, a treatment plan was created using the GRID block and also by creating a GRID pattern using the multi-leaf collimator. The percent depth doses measured with film showed that there is a shift of the dmax towards shallower depths for both energies (6 MV and 18 MV) under investigation. It was observed that the skin dose at the GRID openings was higher than the corresponding open field by a factor as high as 50% for both photon energies. The profiles showed the transmission under the block was in the order of 15-20% for 6 MV and 30% for 18 MV. The MUs calculated for a real patient using the block were about 80% less than the corresponding MUs for the same plan using the multileaf collimator to define the GRID. Based on this investigation, this brass GRID compensator is a viable alternative to other solid compensators or MLC-based fields currently in use. Its ease of creation and use give it decided advantages. Its ability to be created once and used for multiple patients (by varying the collimation of the linear accelerator jaws) makes it attractive from a cost perspective. We believe this compensator can be put to clinical use, and will allow more centers to offer GRID therapy to their patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation-induced bystander effect following hypo- fraction technique of grid therapy by use of sensitive molecular markers

Introduction: Radiation-induced bystander effect (RIBE) is a well-known response associated with the induction of radiation effects in non-irradiated cells via signaling of hit ones. As this so-called phenomenon has been largely investigated in low dose levels, few studies focused on higher dose levels such as grid therapy. Grid therapy or spatially fractionated gri...

متن کامل

Management of bulky high-grade pleomorphic sarcoma using grid therapy technique

In the present study, a case was reported concerning a patient with a bulky extremity soft tissue sarcoma treated with spatially fractionated Grid therapy and then followed by standard external beam radiotherapy. Treatment was performed using a Grid block to deliver 15 Gy in one fraction. There was one week interval break before EBRT treatment with 50 Gy in 25 fractions for the neoadjuvant exte...

متن کامل

Evaluation of dosimetric characteristics of a grid block fabricated for Mega-voltage grid therapy purposes

Background: In conventional radiation therapy, regarding normal tissue tolerance, the treatment of bulk tumors is one of the remaining challenges. Grid Radiation Therapy (GRT) is a technique to deliver high doses, approximately 15 – 20 Gy per fraction, to several small volumes located in a large radiation field. This can be performed using a grid block. The current work has concentrate...

متن کامل

The evaluation of change in attenuation coefficient of cerrobend block used for radiation protection of healthy tissues in megavoltage photon radiation therapy after multiple melting

Introduction: Protecting the vital organs in radiation therapy is one of the most important issues. Cerrobend alloy, the most common material used as the shield, is melted several times and used for different patients. In this study changes in attenuation coefficient of cerrobend due to melting was investigated.   Materials and Methods: In melting furnace, ...

متن کامل

Stereotactic Radiosurgery/Radiotherapy: A Historical Review

"Stereotactic" is an exact radiotherapy treatment modality which implements invasive and non-invasive facilities for improving precise dose delivery. Stereotactic refers to three-dimensional localization of a specific point in space by a unique set of coordinates that relate to a fixed external reference frame. An accurate delivery of radiation is attainable using these techniques with high pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2010