Survey of Image quality and Patient Dose in Simple Radiographic Examinations in Madagascar: Initial results
نویسنده
چکیده
The purpose of this study is to survey image quality and patient doses in radiographic examinations and to perform comparisons with the international Diagnostic Reference Levels (DRLs). This study is part of an International Atomic energy Agency (IAEA) project (RAF/9/033) and one public hospital and two private hospitals were selected. The rate of unsatisfactory images and image qualities grade were noted, and causes for poor image quality were investigated. Doses delivered to patients were determined in terms of entrance skin dose (ESD) based on X-ray tube output measurements and X-ray exposure parameters. Corrective actions were taken mainly in terms of field size and exposure parameters adjustment and data were recollected. The image quality was improved up to 35 % in these three hospitals. Results showed that there is a large variation of patient doses for common examination in three hospitals. Patient dose reductions ranging from 2 to 82% were achieved. Comparisons of dose levels with IAEA Guidance Levels (GLs) after implementing corrective actions showed that patient doses are lower than reference levels except for chest exam in two hospitals and skull in one hospital. Actions are under way to extend measurements to a national level in order to establish national GLs. Keywords— Radiography, patient dose, optimization, radiation protection
منابع مشابه
A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography
Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...
متن کاملOptimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations
IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...
متن کاملEffects of Kilovoltage on Image Quality and Entrance Surface Dose in Lumbar Spine Digital Radiography
Introduction: Digital radiography possesses a wide dynamic range and has a major advantage in producing an acceptable image of diagnostic value even though overexposure occurs. Lumbar spine (LS) radiography is the most common examinations that gives high radiation dose to patients and accounts for the highest collective population dose of any conventional radiographic ...
متن کاملPrimary efforts to optimize image quality in chest direct digital radiography of pediatric patient (for the age group 0 to 1 and 1 to 5 years) with survey some effective parameters in image quality and patient dose
Introduction: This study, evaluate pediatric digital radiography. Due to the high rates of this test and the high sensitivity of children to ionizing radiation in comparison with adults, it is attempted to achieve near optimal conditions by reducing the dose and maintaining the image quality. The object of the study is to change the irradiation parameters such as kV and mA and ...
متن کاملMeasurement of Entrance Skin Dose and Effective Dose in The most Common Diagnostic radiology Examinations in Jiroft, Iran
Introduction: Medical uses of radiation have grown very rapidly over in the past two decades, medical uses represent the largest source of exposure to people, The most important methods in medical diagnosis are the useses of diagnostic radiology exams. Although the use of these methods is very beneficial for the treatment of patients, but ionizing radiation produces ion pairs, ...
متن کامل