Attachment of PMMA cement to bone: force measurements in rats.

نویسندگان

  • R Skripitz
  • P Aspenberg
چکیده

The attachment of an implant material to bone relates to surface roughness and surface chemistry. There is a relatively low chemical bonding strength of so-called bioactive surfaces. Hydroxyapatite interfaces typically have an interfacial tensile strength of 0.15-1.5 MPa. An attachment force similar to that of bioactive surfaces might also be reached through mechanical interlock with ordinary bone cement. This study measured bone cement interfacial tensile strength for polished (R(a) 0.5 microm) and regular (R(a) 4.8 microm) vacuum mixed PMMA bone cement. Bone bonding was evaluated by a detachment test. We used unloaded cement surfaces, which could be detached from the bone. Titanium plates were developed such that a cement fill was contained within a plate, which was contained within a titanium holder. The cement surface came into contact with traumatized bone only, and the rest of the plate had no contact with tissue. The cement surface was either polished or left untreated after conventional preparation. Four weeks later, the plates were detached from the bone by a perpendicular force. The detaching load of the polished cement surface never exceeded 0.07 MPa, whereas for unpolished cement there was a load up to 0.9 MPa. The results suggest that surface irregularities and microinterlock enable an attachment that can resist tension between bone and a cement surface.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physical characterization and osteogenic activity of the quaternized chitosan-loaded PMMA bone cement.

Gentamicin-loaded polymethylmethacrylate (PMMA), widely used for primary cemented arthroplasty and revision surgery for preventing or treating infections, may lead to the evolution of antibiotic-resistant bacteria and dysfunction of osteogenic cells, which further influence the osteointegration of bone cement. In a previous study, we reported that a new quaternized chitosan derivative (hydroxyp...

متن کامل

The Most Appropriate Reconstruction Method Following Giant Cell Tumor Curettage: A Biomechanical Approach

Giant cell tumor (GCT) is a primary and benign tumor of bone, albeit locally aggressive in some cases, such as in the epi-metaphyseal region of long bones, predominantly the distal end of femur and proximal end of tibia (1). There are a variety of treatments for a bone affected by GCT, ranging from chemotherapy, radiotherapy, embolization, and cryosurgery, to surgery with the use of chemical or...

متن کامل

Foreign body granuloma after bone cement augmentation of pedicle screws for osteoporotic spinal surgery: A case report

Osteoporosis causes a decrease in bone mineral density. To overcome the decrease in fixation strength, a variety of techniques and devices have been developed, including cement augmentation of pedicle screws. Polymethyl methacrylate (PMMA), is commonly known as bone cement, and is widely used for implant fixation in various orthopaedic and spine surgery. In general, PMMA augmentation of pedicle...

متن کامل

Inhibition of Staphylococcus epidermidis Biofilms Using Polymerizable Vancomycin Derivatives

BACKGROUND Biofilm formation on indwelling medical devices is a ubiquitous problem causing considerable patient morbidity and mortality. In orthopaedic surgery, this problem is exacerbated by the large number and variety of material types that are implanted. Metallic hardware in conjunction with polymethylmethacrylate (PMMA) bone cement is commonly used. QUESTIONS/PURPOSES We asked whether po...

متن کامل

Fatigue and biocompatibility properties of a poly(methyl methacrylate) bone cement with multi-walled carbon nanotubes.

Composites of multi-walled carbon nanotubes (MWCNT) of varied functionality (unfunctionalised and carboxyl and amine functionalised) with polymethyl methacrylate (PMMA) were prepared for use as a bone cement. The MWCNT loadings ranged from 0.1 to 1.0 wt.%. The fatigue properties of these MWCNT-PMMA bone cements were characterised at MWCNT loading levels of 0.1 and 0.25 wt.% with the type and wt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomaterials

دوره 20 4  شماره 

صفحات  -

تاریخ انتشار 1999