Dose-volume comparison of proton therapy and intensity-modulated radiotherapy for prostate cancer.
نویسندگان
چکیده
PURPOSE The contrast in dose distribution between proton radiotherapy (RT) and intensity-modulated RT (IMRT) is unclear, particularly in regard to critical structures such as the rectum and bladder. METHODS AND MATERIALS Between August and November 2006, the first 10 consecutive patients treated in our Phase II low-risk prostate proton protocol (University of Florida Proton Therapy Institute protocol 0001) were reviewed. The double-scatter proton beam plans used in treatment were analyzed for various dosimetric endpoints. For all plans, each beam dose distribution, angle, smearing, and aperture margin were optimized. IMRT plans were created for all patients and simultaneously analyzed. The IMRT plans were optimized through multiple volume objectives, beam weighting, and individual leaf movement. The patients were treated to 78 Gray-equivalents (GE) in 2-GE fractions with a biologically equivalent dose of 1.1. RESULTS All rectal and rectal wall volumes treated to 10-80 GE (percentage of volume receiving 10-80 GE [V(10)-V(80)]) were significantly lower with proton therapy (p < 0.05). The rectal V(50) was reduced from 31.3% +/- 4.1% with IMRT to 14.6% +/- 3.0% with proton therapy for a relative improvement of 53.4% and an absolute benefit of 16.7% (p < 0.001). The mean rectal dose decreased 59% with proton therapy (p < 0.001). For the bladder and bladder wall, proton therapy produced significantly smaller volumes treated to doses of 10-35 GE (p < 0.05) with a nonsignificant advantage demonstrated for the volume receiving < or =60 GE. The bladder V(30) was reduced with proton therapy for a relative improvement of 35.3% and an absolute benefit of 15.1% (p = 0.02). The mean bladder dose decreased 35% with proton therapy (p = 0.002). CONCLUSION Compared with IMRT, proton therapy reduced the dose to the dose-limiting normal structures while maintaining excellent planning target volume coverage.
منابع مشابه
Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer
Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...
متن کاملStep-and-Shoot versus Compensator-based IMRT: Calculation and Comparison of Integral Dose in Non-tumoral and Target Organs in Prostate Cancer
Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...
متن کاملComparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy
Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...
متن کاملThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کامل3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
متن کامل3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk
Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of radiation oncology, biology, physics
دوره 70 3 شماره
صفحات -
تاریخ انتشار 2008