MD-Logic overnight control for 6 weeks of home use in patients with type 1 diabetes: randomized crossover trial.

نویسندگان

  • Revital Nimri
  • Ido Muller
  • Eran Atlas
  • Shahar Miller
  • Aviel Fogel
  • Natasa Bratina
  • Olga Kordonouri
  • Tadej Battelino
  • Thomas Danne
  • Moshe Phillip
چکیده

OBJECTIVE We evaluated the effect of the MD-Logic system on overnight glycemic control at patients' homes. RESEARCH DESIGN AND METHODS Twenty-four patients (aged 12-43 years; average A1c 7.5 ± 0.8%, 58.1 ± 8.4 mmol/mol) were randomly assigned to participate in two overnight crossover periods, each including 6 weeks of consecutive nights: one under closed loop and the second under sensor-augmented pump (SAP) therapy at patients' homes in real-life conditions. The primary end point was time spent with sensor glucose levels below 70 mg/dL (3.9 mmol/L) overnight. RESULTS Closed-loop nights significantly reduced time spent in hypoglycemia (P = 0.02) and increased the percentage of time spent in the target range of 70-140 mg/dL (P = 0.003) compared with nights when the SAP therapy was used. The time spent in substantial hyperglycemia above 240 mg/dL was reduced by a median of 52.2% (interquartile range [IQR] 4.8, 72.9%; P = 0.001) under closed-loop control compared with SAP therapy. Overnight total insulin doses were lower in the closed-loop nights compared with the SAP nights (P = 0.04). The average daytime glucose levels after closed-loop operation were reduced by a median of 10.0 mg/dL (IQR -2.7, 19.2; P = 0.017) while lower total insulin doses were used (P = 0.038). No severe adverse events occurred during closed-loop control; there was a single event of severe hypoglycemia during a control night. CONCLUSIONS The long-term home use of automated overnight insulin delivery by the MD-Logic system was found to be a feasible, safe, and an effective tool to reduce nocturnal hypoglycemia and improve overnight glycemic control in subjects with type 1 diabetes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Selenium on Micro-Albuminuria in Diabetic Patients: A Randomized Clinical Trial

Objective: Oxidative stress plays an important role in the onset and progression of diabetic nephropathy. So antioxidant agents may be one of the key treatment strategies for prevention of diabetic nephropathy progression .The aim of this study was to determine the effect of selenium (Se) on micro-albuminuria in type 2 diabetic (T2DM) patients. Materials and Methods: This study was a clinical ...

متن کامل

Effects of Urtica dioica supplementation on blood lipids, hepatic enzymes and nitric oxide levels in type 2 diabetic patients: A double blind, randomized clinical trial

Objective: Oxidative stress plays an important role in the development of diabetic complications including metabolic abnormality-induced diabetic micro-vascular and macro-vascular complications. Urtica dioica L. (U. dioica) has been traditionally used in Iranian medicine as an herbal remedy for hypoglycemic or due to its anti-inflammatory properties. The aim of the present study was to evaluate...

متن کامل

Unsupervised home use of an overnight closed-loop system over 3–4 weeks: a pooled analysis of randomized controlled studies in adults and adolescents with type 1 diabetes

AIMS To compare overnight closed-loop and sensor-augmented pump therapy in patients with type 1 diabetes by combining data collected during free-living unsupervised randomized crossover home studies. METHODS A total of 40 participants with type 1 diabetes, of whom 24 were adults [mean ± standard deviation (s.d.) age 43 ± 12 years and glycated haemoglobin (HbA1c) 8.0 ± 0.9%] and 16 were adoles...

متن کامل

Night glucose control with MD-Logic artificial pancreas in home setting: a single blind, randomized crossover trial-interim analysis.

BACKGROUND Artificial pancreas (AP) systems have shown an improvement in glucose control and a reduced risk of nocturnal hypoglycemia under controlled conditions but remain to be evaluated under daily-life conditions. OBJECTIVE To assess the feasibility, safety, and efficacy of the MD-Logic AP in controlling nocturnal glucose levels in the patient's home. METHODS Two-arm study, each coverin...

متن کامل

The Effect of Probiotic Yogurt on Blood Glucose and cardiovascular Biomarkers in Patients with Type II Diabetes: A Randomized Controlled Trial

Background: Given the high prevalence of type II diabetes and its complications, the evidence regarding the beneficial effects of probiotic yogurt on some cardiovascular biomarkers in diabetic patients is worthy of investigation. Aim: To investigate the effect of probiotic yogurt on blood glucose level and cardiovascular biomarkers in patients with type II diabetes. Method:This randomized, clin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes care

دوره 37 11  شماره 

صفحات  -

تاریخ انتشار 2014