Do "optimal" conditions improve distortion product otoacoustic emission test performance?
نویسندگان
چکیده
OBJECTIVES To determine whether an "optimal" distortion product otoacoustic emission (DPOAE) protocol that (1) used optimal stimulus levels and primary-frequency ratios for each f2, (2) simultaneously measured 2f2 - f1 and 2f1 - f2 distortion products, (3) controlled source contribution, (4) implemented improved calibration techniques, (5) accounted for the influence of middle ear reflectance, and (6) applied multivariate analyses to DPOAE data results in improved accuracy in differentiating between normal-hearing and hearing-impaired ears, compared with a standard clinical protocol. DESIGN Data were collected for f2 frequencies ranging from 0.75 to 8 kHz in 28 normal-hearing and 78 hearing-impaired subjects. The protocol included a control condition incorporating standard stimulus levels and primary-frequency ratios calibrated with a standard SPL method and three experimental conditions using optimized stimuli calibrated with an alternative forward pressure level method. The experimental conditions differed with respect to the level of the reflection-source suppressor tone and included conditions referred to as the null suppressor (i.e., no suppressor tone presented), low-level suppressor (i.e., suppressor tone presented at 58 dB SPL), and high-level suppressor (i.e., suppressor tone presented at 68 dB SPL) conditions. The area under receiver operating characteristic (A(ROC)) curves and sensitivities for fixed specificities (and vice versa) were estimated to evaluate test performance in each condition. RESULTS A(ROC) analyses indicated (1) improved test performance in all conditions using multivariate analyses, (2) improved performance in the null suppressor and low suppressor experimental conditions compared with the control condition, and (3) poorer performance below 4 kHz with the high-level suppressor. As expected from A(ROC), sensitivities for fixed specificities and specificities for fixed sensitivities were highest for the null suppressor and low suppressor conditions and lowest for standard clinical procedures. The influence of 2f2 - f1 and reflectance on test performance were negligible. CONCLUSIONS Predictions of auditory status based on DPOAE measurements in clinical protocols may be improved by the inclusion of (1) optimized stimuli, (2) alternative calibration techniques, (3) low-level suppressors, and (4) multivariate analyses.
منابع مشابه
Evaluation of Distortion and Transient Evoked Otoacoustic Emission in Tinnitus Patients with Normal Hearing
Introduction: Tinnitus is a perception of sound without external source. The exact etiology of tinnitus is not fully understood, although some researchers believe that the condition usually starts in the cochlea. The aim of this study was to determine the potential contribution of outer hair cell dysfunction to chronic tinnitus, by application of Distortion-Product Evoked Otoacoustic Emission (...
متن کاملConventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL
BACKGROUND Noise most frequently affects hearing system, as it may typically cause a bilateral, progressive sensorineural hearing loss at high frequencies. OBJECTIVES This study was designed to compare three different methods to evaluate noise-induced hearing loss (conventional audiometry, high-frequency audiometry, and distortion product otoacoustic emission). MATERIAL AND METHODS This was...
متن کاملDistortion product otoacoustic emissions to single and simultaneous tone pairs.
Distortion product otoacoustic emissions (DPOAEs) evoked by single tone pairs and three simultaneous tone pairs were recorded in 60 normal-hearing adult ears. The purpose was to replicate a previous study using the commercially available probe assembly of the Grason Stadler GSI 60 and including ear of presentation in the statistical analysis along with frequency and condition. DPOAE levels were...
متن کاملDistortion product otoacoustic emissions in sheep before and after hyperinsulinemia induction.
UNLABELLED Transient evoked otoacoustic emissions and distortion product otoacoustic emissions have gained significant importance in the identification of cochlear alterations. AIM To record distortion product thresholds through the monitoring of otoacoustic emissions in normal conditions and in the presence of electrophysiologic changes in cochlear outer hair cells in sheep after hyperinsuli...
متن کاملAttention effects on distortion-product otoacoustic emissions with contralateral speech stimuli.
This study investigated the effect of selective attention on the distortion-product otoacoustic emission (DPOAE) level through the use of environmentally meaningful, contralateral auditory stimuli. Four different conditions were used for measurement: quiet, contralateral noise, contralateral speech (unattended), and contralateral speech (attended). A statistically significant suppression effect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ear and hearing
دوره 32 2 شماره
صفحات -
تاریخ انتشار 2011