Impact of time-related factors on biologically accurate radiotherapy treatment planning
نویسندگان
چکیده
BACKGROUND The incomplete repair (IR) model expresses the cell repair effect from radiation-induced damage over time, which is given little consideration in actual treatment planning. By incorporating the IR model into the normal tissue complication probability (NTCP), the accuracy and safety of treatment plan evaluations concerning the effect of repair can be improved. This study aims to evaluate the impact of incorporating the IR model into the NTCP by varying time-related factors such as the repair half-time (T1/2) and the junction-shift sc3hedule in craniospinal irradiation (CSI). METHODS CSI was planned retrospectively, and the NTCP of the spinal cord was calculated with the IR model for values of T1/2 from 1 to 10 h. The NTCP in the case of changing the junction-shift schedule was also examined in the same manner. RESULTS The NTCP with the IR model increased with increasing T1/2, which is prominent for the larger T1/2. By changing the junction-shift schedule, the NTCP with the IR model decreased when adjacent fields overlapped. CONCLUSIONS The IR model is a valuable addition to treatment planning because it enables the NTCP to be evaluated including the effect of repair and differences in scheduling to be reflected in the NTCP. However, these are largely dependent on the value of the T1/2.
منابع مشابه
Developing a mobile application for usual calculations of radiotherapy physics
Introduction: Successful radiotherapy requires the precise application of a radiation dose to cancerous tissue, which can be achieved by the design of proper treatment methods by radiotherapy physicists. Tasks performed by radiotherapy physicists include verifying the accuracy of dose calculations, correct treatment planning and the proper functioning of accelerators. They are...
متن کاملComparing the results of 3D treatment planning and practical dosimetry in craniospinal radiotherapy using Rando phantom
Background: Craniospinal radiotherapy faces technical challenges which are due to the sensitivity of the location in which the gross tumor is, and to organs at risk around planning target volume. Using modern treatment planning systems causes a reduction in the complexities of the treatment techniques. The most effective method to assess the dosimetric accuracy and the validity of the ...
متن کاملEvaluation of Effect of Different Computed Tomography Scanning Protocols on Hounsfield Unit and Its Impact on Dose Calculation by Treatment Planning System
Introduction: In radiotherapy treatment planning system (TPS), basic input is the data from computed tomography (CT) scan, which takes into account the effect of inhomogeneities in dose calculations. Measurement of CT numbers may be affected by scanner-specific parameters. Therefore, it is important to verify the effect of different CT scanning protocols on Hounsfield unit (HU) and its impact o...
متن کاملInvestigating the effects of different kernels used for CT image reconstruction on dose distributions in treatment planning of kidney cancer radiotherapy
Introduction: The quality of CT images used for treatment planning of cancer patients is an important issue in accurate outlining of the tumor volume and organs at risk. Different kernels in CT scanner systems are available for improving the image quality. Applying these kernels on CT images will change the CT numbers and electron density of tissues, conse...
متن کاملAn Approach in Radiation Therapy Treatment Planning: A Fast, GPU-Based Monte Carlo Method
Introduction: An accurate and fast radiation dose calculation is essential for successful radiation radiotherapy. The aim of this study was to implement a new graphic processing unit (GPU) based radiation therapy treatment planning for accurate and fast dose calculation in radiotherapy centers. Materials and Methods: A program was written for parallel runnin...
متن کامل