Determination of bromine in regulated foods with a field-portable X-ray fluorescence analyzer.

نویسنده

  • David L Anderson
چکیده

A field-portable X-ray fluorescence analyzer, factory-calibrated for soil analysis, was used to measure bromine (Br) mass fractions in reference materials, flour, bakery products, malted barley, selected U.S. Food and Drug Administration Total Diet Study foods, and other food products. By using a calibration based on instrumental neutron activation analysis results for Br in reference materials, accurate quantitative results, confirmed by z-scores, could be obtained for mass fractions of about 2-55 mg/kg. These results confirmed accuracy of results (with larger uncertainties) obtained by applying a simple correction factor to the analyzer's output value. Results showed that very short analysis times (<2 min) would be needed to screen foods for Br content at regulatory levels for brominated and enriched brominated flour (24 mg/kg Br) and whole wheat flour and bakery products (36 mg/kg Br). Feasibility for determination of Br in malted barley at the regulatory level (75 mg/kg Br) was demonstrated, but quantitative results at that level could not be assured because no reference material with a suitable mass fraction was available. Br mass fractions for all foods tested were well below regulatory levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field portable X-Ray fluorescence for rapid analysis Of titanium dioxide on air filters

Field portable X-Ray fluorescence for rapid analysis Of titanium dioxide on air filters. ii ACKNOWLEDGMENTS This study would not have been possible without the help from several different resources. I would like to thank Kent Candee for the access to the field portable x-ray fluorescence analyzer, which was my biggest concern from the beginning of the project. I would also like to thank Pam Kos...

متن کامل

Determination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays

Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation d...

متن کامل

Household Exposures to Polybrominated Diphenyl Ethers (PBDEs) in a Wisconsin Cohort

BACKGROUND Human exposure to polybrominated diphenyl ethers (PBDEs) is virtually universal in the United States. Although the uses of these chemicals as flame retardants in fabrics, foams, and plastics are well defined, human exposure pathways are not well understood. OBJECTIVES This study was designed to assess current PBDE body burdens and identify residential sources of exposure among 29 m...

متن کامل

کاربرد دستگاه XRF پرتابل در مطالعات باستان‌سنجی مواد فرهنگی تاریخی

Study of cultural and historical materials excavated from the archaeological excavation is one of the most important goals of Archaeometry, in order to answer a lot of questions in archaeology. In this regard, elemental analysis is important factors in the realization of this aim. Numerous analytical methods have been used for this purpose traditionally. Among them, X-ray fluorescence spectrosc...

متن کامل

Method 6200 - Field Portable X-ray Fluorescence Spectrometry for the Determination of Elemental Concentrations in Soil and Sedi

1.1 This method is applicable to the in situ and intrusive analysis of the 26 analytes listed in Table 1 for soil and sediment samples. Some common elements are not listed in Table 1 because they are considered "light" elements that cannot be detected by field portable x-ray fluorescence (FPXRF). They are: lithium, beryllium, sodium, magnesium, aluminum, silicon, and phosphorus. Most of the ana...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 92 2  شماره 

صفحات  -

تاریخ انتشار 2009