Comparison of agar dilution, disk diffusion, MicroScan, and Vitek antimicrobial susceptibility testing methods to broth microdilution for detection of fluoroquinolone-resistant isolates of the family Enterobacteriaceae.

نویسندگان

  • C D Steward
  • S A Stocker
  • J M Swenson
  • C M O'Hara
  • J R Edwards
  • R P Gaynes
  • J E McGowan
  • F C Tenover
چکیده

Fluoroquinolone resistance appears to be increasing in many species of bacteria, particularly in those causing nosocomial infections. However, the accuracy of some antimicrobial susceptibility testing methods for detecting fluoroquinolone resistance remains uncertain. Therefore, we compared the accuracy of the results of agar dilution, disk diffusion, MicroScan Walk Away Neg Combo 15 conventional panels, and Vitek GNS-F7 cards to the accuracy of the results of the broth microdilution reference method for detection of ciprofloxacin and ofloxacin resistance in 195 clinical isolates of the family Enterobacteriaceae collected from six U.S. hospitals for a national surveillance project (Project ICARE [Intensive Care Antimicrobial Resistance Epidemiology]). For ciprofloxacin, very major error rates were 0% (disk diffusion and MicroScan), 0.9% (agar dilution), and 2.7% (Vitek), while major error rates ranged from 0% (agar dilution) to 3.7% (MicroScan and Vitek). Minor error rates ranged from 12.3% (agar dilution) to 20.5% (MicroScan). For ofloxacin, no very major errors were observed, and major errors were noted only with MicroScan (3.7% major error rate). Minor error rates ranged from 8.2% (agar dilution) to 18.5% (Vitek). Minor errors for all methods were substantially reduced when results with MICs within +/-1 dilution of the broth microdilution reference MIC were excluded from analysis. However, the high number of minor errors by all test systems remains a concern.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of the VITEK 2, disk diffusion, etest, broth microdilution, and agar dilution susceptibility testing methods for colistin in clinical isolates, including heteroresistant Enterobacter cloacae and Acinetobacter baumannii strains.

Increasing antibiotic resistance in gram-negative bacteria has recently renewed interest in colistin as a therapeutic option. The increasing use of colistin necessitates the availability of rapid and reliable methods for colistin susceptibility testing. We compared seven methods of colistin susceptibility testing (disk diffusion, agar dilution on Mueller-Hinton [MH] and Isosensitest agar, Etest...

متن کامل

Comparison of five methods, including the PDM Epsilometer test (E test), for antimicrobial susceptibility testing of Pseudomonas aeruginosa.

The antimicrobial susceptibilities of 100 clinical isolates of Pseudomonas aeruginosa to six antipseudomonal antibiotics were tested by five methods: the National Committee for Clinical Laboratory Standards (NCCLS) methods for broth microdilution, agar dilution, and agar disk diffusion; the Vitek Automicrobic System method (Vitek Systems, Hazelwood, Mo.); and the PDM Epsilometer test (E test) (...

متن کامل

Antimicrobial susceptibility testing of carbapenems: multicenter validity testing and accuracy levels of five antimicrobial test methods for detecting resistance in Enterobacteriaceae and Pseudomonas aeruginosa isolates.

From January 1996 to May 1999, Project ICARE (Intensive Care Antimicrobial Resistance Epidemiology) received 448 nonduplicate clinical isolates of Enterobacteriaceae and Pseudomonas aeruginosa that were reported to be imipenem intermediate or resistant. However, broth microdilution (BMD) confirmatory testing at the Project ICARE central laboratory confirmed this result in only 11 of 123 (8.9%) ...

متن کامل

Performance of eight methods, including two new rapid methods, for detection of oxacillin resistance in a challenge set of Staphylococcus aureus organisms.

Using a set of 55 Staphylococcus aureus challenge organisms, we evaluated six routine methods (broth microdilution, disk diffusion, oxacillin agar screen, MicroScan conventional panels, MicroScan rapid panels, and Vitek cards) currently used in many clinical laboratories and two new rapid methods, Velogene and the MRSA-Screen, that require less than a day to determine the susceptibility of S. a...

متن کامل

Wide variability in Pseudomonas aeruginosa aminoglycoside results among seven susceptibility testing procedures.

Seven commonly used antimicrobial susceptibility testing methods were used to test the susceptibility of 150 isolates of Pseudomonas aeruginosa against gentamicin, tobramycin, amikacin, carbenicillin, and piperacillin. Results were compared with respect to the susceptibility characteristics of the population of isolates as defined by each method. Conventional methods included agar disk diffusio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 1999