Fabrication of an Implant-Supported Orbital Prosthesis with Bar-Magnetic Attachment: A Clinical Report

نویسندگان

  • Shima Aalaei
  • Abolhassan Abolhassani
  • Fatemeh Nematollahi
  • Elaheh Beyabanaki
  • Amir Ali Mangoli
چکیده

Implant-supported craniofacial prostheses are made to restore defective areas in the face and cranium. This clinical report describes a technique for fabrication of an orbital prosthesis with three adjacent implants in the left lateral orbital rim of a 60-year-old woman. Selection of appropriate attachment system (individual magnetic abutments versus bar-clip attachment) for implant-supported orbital prostheses depends upon the position of implants. Bar-magnetic attachment has been selected as the retention mechanism in the present case.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Case Report: Implant-Supported Removable Partial Denture In A Mandibular Kennedy CL II: A Clinical Report

Abstract The implant-supported removable partial dentures should be an alternative to conventional removable partial dentures and implant-supported fixed partial prostheses when the implant’s insertion is confined by bone height and thickness. Placing a single implant in the posterior region would modify the Kennedy Class II configuration to a Kennedy Class III and increase the stability a...

متن کامل

Partial removable prosthesis in a patient with unilateral maxillectomy: A case report

BACKGROUND AND AIM: Maxillofacial defects due to malignant or benign tumors or congenital defects often result in complications such as the impairment of facial aesthetic, mastication, speech, and swallowing. Remedy of these defects, especially in a dentate patient is an important challenge in prosthodontics. Maxillectomy can lead to severe anatomical changes f...

متن کامل

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

Use of an Implant O-Ring Attachment for the Tooth Supported Mandibular Overdenture: A Clinical Report

Retention of a mandibular denture can be achieved by an implant-retained or natural tooth-retained bar and stud attachment in the anterior segment of the mandible. The same design principles holds true for both implant-retained and tooth-retained methods of anchoring the bar and stud attachment. A simple and cost effective treatment for more complex implant overdenture is the concept of convent...

متن کامل

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2015