Skin electrodes transduced signals to the bladder resulting in ameliorated hypomotility in a rabbit model of diabetes☆

نویسندگان

  • Xinmin Wang
  • Qirui Fu
  • Qingmei Zhang
  • Ping Xu
  • Lin Cao
  • Meng Xue
  • Wei Wang
چکیده

Electric signals from a chest skin electrode can be conducted to the heart and activate contraction. In the present study, normal and diabetic rabbits were stimulated by skin electrode on the abnormal bladder projection area using three levels of exporting voltage (5.84 V, 8.00 V, and 11.00 V). Results demonstrated significantly attenuated electric signals from both groups, in particular the diabetes group. The skin electrode signals were conducted to the bladders, and all vesical signals increased according to strength of stimulating signals from the skin electrode. However, vesical signals from diabetic rabbits were less than those from normal rabbits at the same stimulating strength of exporting voltage. Vesical pressures from the two groups increased along with increased vesical signals, but vesical pressure was less those from diabetic rabbits than in normal rabbits (basic status and different stimulating levels). Linear correlation analysis showed a significantly positive correlation between vesical pressure and signal. These results demonstrated that electric signals from skin electrodes resulted in increased vesical pressure, and vesical pressure increased along with stimulation strength.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EMG-based wrist gesture recognition using a convolutional neural network

Background: Deep learning has revolutionized artificial intelligence and has transformed many fields. It allows processing high-dimensional data (such as signals or images) without the need for feature engineering. The aim of this research is to develop a deep learning-based system to decode motor intent from electromyogram (EMG) signals. Methods: A myoelectric system based on convolutional ne...

متن کامل

Extraction of Sensory part of Ulnar Nerve Signal Using Blind Source Separation Method

A recorded nerve signal via an electrode is composed of many evokes or action potentials, (originated from individual axons) which may be considered as different initial sources. Recovering these primitive sources in its turn may lead us to the anatomic originations of a nerve signal which will give us outstanding foresights in neural rehabilitations. Accordingly, clinical interests may be r...

متن کامل

Ultrasonographic Evaluation of the Urinary System in New Zealand White Rabbit and Tolai Hare

Ultrasonographic examination of urinary system (kidney and urinary bladder) was conducted in New Zealand white rabbit [NZwr] and Tolai hare (Lepus tolai). Ultrasound images of the kidney and urinary bladder were evaluated on fifteen healthy rabbits of New Zealand white rabbit and another fifteen Tolai hares. The healthy rabbits were 8-12 months old (mean = 9.3 months), of both sexes and weighed...

متن کامل

Quantative Evaluation of the Efficiency of Facial Bio-potential Signals Based on Forehead Three-Channel Electrode Placement For Facial Gesture Recognition Applicable in a Human-Machine Interface

Introduction: Today, facial bio-potential signals are employed in many human-machine interface applications for enhancing and empowering the rehabilitation process. The main point to achieve that goal is to record appropriate bioelectric signals from the human face by placing and configuring electrodes over it in the right way. In this paper, heuristic geometrical position and configuration of ...

متن کامل

Interpretation of Electrochemical Noise Signals Arising from Symmetrical and Asymmetrical Electrodes Made of Polypyrrole Coated Mild Steel

This article applies the standard deviation of partial signal (SDPS) plots of electrochemical noise (EN) current signals originating from corrosion events on the symmetrical and asymmetrical electrodes made of uncoated and polypyrrole (PPy)-coated mild steel alloy in 4000 ppm NaCl+1000 ppm NaNO2 solution. Signal recording was performed after 30, 60, 90 min and 24 h from immersion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012