Direct measurement of the photoelectric response time of bacteriorhodopsin via electro-optic sampling.
نویسندگان
چکیده
The photovoltaic signal associated with the primary photochemical event in an oriented bacteriorhodopsin film is measured by directly probing the electric field in the bacteriorhodopsin film using an ultrafast electro-optic sampling technique. The inherent response time is limited only by the laser pulse width of 500 fs, and permits a measurement of the photovoltage with a bandwidth of better than 350 GHz. All previous published studies have been carried out with bandwidths of 50 GHz or lower. We observe a charge buildup with an exponential formation time of 1.68 +/- 0.05 ps and an initial decay time of 31.7 ps. Deconvolution with a 500-fs Gaussian excitation pulse reduces the exponential formation time to 1.61 +/- 0.04 ps. The photovoltaic signal continues to rise for 4.5 ps after excitation, and the voltage profile corresponds well with the population dynamics of the K state. The origin of the fast photovoltage is assigned to the partial isomerization of the chromophore and the coupled motion of the Arg-82 residue during the primary event.
منابع مشابه
Single-shot measurement of terahertz electromagnetic pulses by use of electro-optic sampling.
We demonstrate a simple scheme for capturing the temporal waveforms of a freely propagating terahertz electromagnetic transient in a single shot. The method relies on electro-optic sampling in a noncollinear geometry for the terahertz radiation and the visible probe beam, coupled with multichannel detection. The approach provides time resolution that is comparable to that of conventional electr...
متن کاملEnhancement of photoelectric response of bacteriorhodopsin by multilayered WO3 x H2O nanocrystals/PVA membrane.
For the first time, a multilayered WO(3) x H(2)O/PVA membrane on bacteriorhodopsin (bR) is constructed to significantly enhance the photoelectric response of bR by the spillover effect of WO(3) x H(2)O nanocrystals, providing great potential in its important applications in bioelectronics and proton exchange membrane fuel cells.
متن کاملCalibrating photoreceiver response to 110 GHz
We have measured the magnitude and phase responses of a photoreceiver to 110 GHz using a calibrated electro-optic sampling system. The frequency range of the calibration is limited only by our 1 mm coaxial connectors. In this paper, we present a method for accurately characterizing the response of a commercially available photoreceiver to 110 GHz, nearly three times the bit rate of 40 Gb/s opto...
متن کاملWideband THz Time Domain Spectroscopy based on Optical Rectification and Electro-Optic Sampling
We present an analytical model describing the full electromagnetic propagation in a THz time-domain spectroscopy (THz-TDS) system, from the THz pulses via Optical Rectification to the detection via Electro Optic-Sampling. While several investigations deal singularly with the many elements that constitute a THz-TDS, in our work we pay particular attention to the modelling of the time-frequency b...
متن کاملUltrabroadband photoconductive detection: Comparison with free-space electro-optic sampling
The spectral response of a low-temperature-grown GaAs photoconductive ~PC! antenna is compared with that of the electro-optic sampling technique for the frequency region up to 40 THz. The spectral response of the PC antenna for broadband detection is found to be determined by the temporal profile of the number of photocarriers injected by ultrashort optical gate pulses. © 2001 American Institut...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biophysical journal
دوره 85 2 شماره
صفحات -
تاریخ انتشار 2003