Indoor and Outdoor Exposure to Ultrafine, Fine and Microbiologically Derived Particulate Matter Related to Cardiovascular and Respiratory Effects in a Panel of Elderly Urban Citizens

نویسندگان

  • Dorina Gabriela Karottki
  • Michal Spilak
  • Marie Frederiksen
  • Zorana Jovanovic Andersen
  • Anne Mette Madsen
  • Matthias Ketzel
  • Andreas Massling
  • Lars Gunnarsen
  • Peter Møller
  • Steffen Loft
چکیده

To explore associations of exposure to ambient and indoor air particulate and bio-aerosol pollutants with cardiovascular and respiratory disease markers, we utilized seven repeated measurements from 48 elderly subjects participating in a 4-week home air filtration study. Microvascular function (MVF), lung function, blood leukocyte counts, monocyte adhesion molecule expression, C-reactive protein, Clara cell protein (CC16) and surfactant protein-D (SPD) were examined in relation to exposure preceding each measurement. Exposure assessment included 48-h urban background monitoring of PM10, PM2.5 and particle number concentration (PNC), weekly measurements of PM2.5 in living- and bedroom, 24-h measurements of indoor PNC three times, and bio-aerosol components in settled dust on a 2-week basis. Statistically significant inverse associations included: MVF with outdoor PNC; granulocyte counts with PM2.5; CD31 expression with dust fungi; SPD with dust endotoxin. Significant positive associations included: MVF with dust bacteria; monocyte expression of CD11 with PM2.5 in the bedroom and dust bacteria and endotoxin, CD31 expression with dust serine protease; serum CC16 with dust NAGase. Multiple comparisons demand cautious interpretation of results, which suggest that outdoor PNC have adverse effects on MVF, and outdoor and indoor PM2.5 and bio-aerosols are associated with markers of inflammation and lung cell integrity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تراکم PM2.5 در هوای داخل و خارج فروشگاه ها در مرکز شهر ساری

Background and purpose: Ëxposure to respirable particles (PM2.5) causes adverse health effects, such as: respiratory and cardiovascular diseases and eventually death. Çonsidering congested traffic flow in the city center of Sari, it could be expected that exposure of citizens to particulate air pollution would be high. The aim of this study was to survey the concentrations of PM2.5 indoor and o...

متن کامل

Personal, indoor, and outdoor exposures to PM2.5 and its components for groups of cardiovascular patients in Amsterdam and Helsinki.

The aim of the investigation was to assess the relations between pairs of personal, indoor, and outdoor levels of fine particles and their components with respect to effects for older subjects with cardiovascular disease. In the framework of a study funded by the European Union (Exposure and Risk Assessment for Fine and Ultrafine Particles in Ambient Air; referred to as ULTRA)*, panel studies w...

متن کامل

Cardiovascular and lung function in relation to outdoor and indoor exposure to fine and ultrafine particulate matter in middle-aged subjects.

This cross-sectional study investigated the relationship between exposure to airborne indoor and outdoor particulate matter (PM) and cardiovascular and respiratory health in a population-based sample of 58 residences in Copenhagen, Denmark. Over a 2-day period indoor particle number concentrations (PNC, 10-300 nm) and PM2.5 (aerodynamic diameter<2.5 μm) were monitored for each of the residences...

متن کامل

Elemental composition of fine particles: exposure in the general population and influence from different sources

The general population is exposed to particulate air pollution from many different local and regional sources. Examples of local sources are traffic, biomass burning and resuspended dust, while regional sources are dominated by combustion processes from heating, traffic and industries. The overall aim of this thesis was to characterise the personal exposure to trace elements in fine particles, ...

متن کامل

Ultrafine and Fine Particulate Matter Inside and Outside of Mechanically Ventilated Buildings

The objectives of this study were to measure levels of particulate matter (PM) in mechanically ventilated buildings and to improve understanding of filtration requirements to reduce exposure. With the use of an Ultra High Sensitivity Aerosol Spectrometer and an Aerodyne Mass Spectrometer, ultrafine (0.055-0.1 μm) and fine (0.1-0.7 μm) indoor and outdoor PM was measured as a function of time in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2015