A multi-sensor joint detection technology was proposed based on the theory of the high frequency current transformer (HFCT) method, Ultra-high frequency (UHF) method and acoustic emission (AE) method. An experimental partial discharge (PD) testing was applied on XLPE cable with artificial defect signals. The experimental results show that the multi-sensor joint detection technology will help to identify the PD signals from the interference noises and improve the localization accuracy. Streszczenie. Zastosowano wielosensorową metodę badania wyładowania niezupełnego: wysokoczęstotliwościowy transformator prądu oraz metodę emisji akustycznej. Badania przeprowadzono na kablu ze sztucznym sygnałem defektu. Umożliwiło to wydzielenie sygnału z szumów i poprawe dokładności pomiaru lokalizacji. (Badania lokalizacji wyładowania niezupełnego w kablu XLPE przy użyciu techniki multiczujnikowej)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-line Partial Discharge Monitoring System and Data Processing Using WTST-NST Filter for High Voltage Power Cable

Defects inside insulation of HV XLPE cable accessories can lead to partial discharge (PD) activity. When PD activity happens, leakage current may flow through the grounded line. To acquire the PD current signal, one practicable and effective method is placing a high frequency current transformer (HFCT) winding the grounded line. In order to measure the insulation degradation, a partial discharg...

متن کامل

The Application of Partial Discharge Detection for the condition assessment of XLPE Power Cables

Partial discharge (PD) detection is an important means in the condition-based maintenance of high voltage apparatus including crosslinked polyethylene (XLPE) power cables. In this contribution, we introduce the recent work in Shanghai municipal electric power company on the condition-based maintenance of XLPE power cables. As to how to carry out the PD detection in different circumstances, thre...

متن کامل

On-line Partial Discharge Monitor System of XLPE Power Cable Based on Virtual Instrument

High voltage XLPE power cable is a very important part of power system. The degree of electric-tree aging in the cable can be estimated effectually by measuring partial discharge. An on-line partial discharge monitor system of XLPE power cable was developed based on the virtual instrument designing conception. This system has the advantage of wide analog bandwidth, excellent anti-interference a...

متن کامل

A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System

We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD) of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity...

متن کامل

The Propagation of Partial Discharge Pulses in a High Voltage Cable

Partial discharge within the dielectric of HV solid dielectric power cable greatly shortens the cable life. It is desirable to detect and locate the PD in the cable before breakdown occurs. Understanding the phenomena of propagation of the PD pulse in a power cable is fundamental to the detection and location of PDs. In this paper a power cable model represented by a coaxial transmission lossle...