Time-domain algorithm for single-photon laser-Doppler flowmetry at large interoptode spacing in human bone.
نویسندگان
چکیده
A new laser-Doppler flowmeter at large interoptode spacing, based on single-photon counting (single-photon laser-Doppler flowmetry [SP-LDF]) and allowing assessment of blood flow deep in bone tissue, is proposed and implemented. To exploit the advantages of the new SP-LDF hardware, a dedicated simple and efficient time-domain algorithm has been developed. The new algorithm is based on the zero-order moment of the power density spectrum of the ad hoc prefiltered photoelectric current. The SP-LDF has been validated by Monte Carlo simulations, as well as by experimental measurements on a bone tissue phantom for optical flowmeters and on human.
منابع مشابه
Laser-Doppler flowmetry at large interoptode spacing in human tibia diaphysis: Monte Carlo simulations and preliminary experimental results.
Laser-Doppler flowmetry (LDF) is an outstanding tool to monitor blood flow in a continuous and non-invasive way. In this work, we study LDF at large interoptode spacing applied to a human bone model (i.e. tibia diaphysis). To that aim, we first performed an extensive set of Monte Carlo (MC) simulations for 10 and 25 mm interoptode spacing. Second, we have assembled a dedicated LDF instrumentati...
متن کاملBone tissue phantoms for optical flowmeters at large interoptode spacing generated by 3D-stereolithography
A bone tissue phantom prototype allowing to test, in general, optical flowmeters at large interoptode spacings, such as laser-Doppler flowmetry or diffuse correlation spectroscopy, has been developed by 3D-stereolithography technique. It has been demonstrated that complex tissue vascular systems of any geometrical shape can be conceived. Absorption coefficient, reduced scattering coefficient an...
متن کاملPulsatile blood flow in human bone assessed by laser-Doppler flowmetry and the interpretation of photoplethysmographic signals.
Human bone blood flow, mean blood speed and the number of moving red blood cells were assessed (in arbitrary units), as a function of time, during one cardiac cycle. The measurements were obtained non-invasively on five volunteers by laser-Doppler flowmetry at large interoptode spacing. The investigated bones included: patella, clavicle, tibial diaphysis and tibial malleolus. As hypothesized, w...
متن کاملAbsorption and scattering coefficient dependence of laser-Doppler flowmetry models for large tissue volumes.
Based on quasi-elastic scattering theory (and random walk on a lattice approach), a model of laser-Doppler flowmetry (LDF) has been derived which can be applied to measurements in large tissue volumes (e.g. when the interoptode distance is >30 mm). The model holds for a semi-infinite medium and takes into account the transport-corrected scattering coefficient and the absorption coefficient of t...
متن کاملHaemodynamic responses to temperature changes of human skeletal muscle studied by laser-Doppler flowmetry.
Using a small, but very instructive experiment, it is demonstrated that laser-Doppler flowmetry (LDF) at large interoptode spacing represents a unique tool for new investigations of thermoregulatory processes modulating the blood flow of small muscle masses in humans. It is shown on five healthy subjects that steady-state values of blood flow (perfusion) in the thenar eminence muscle group depe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 53 30 شماره
صفحات -
تاریخ انتشار 2014