Power line interference noise removal in ECG-A Comparative study
نویسنده
چکیده
The electrocardiogram has the considerable diagnostic significance, and applications of ECG monitoring are diverse and in wide use. ECG signal after acquisition contains noises such as power line interference, instrumentation noise, external electromagnetic field interference, noise due to random body movements and respiration movements. These noises can be classified according to their frequency content. It is essential to reduce these disturbances in ECG signal to improve accuracy and reliability. The bandwidth of the noise overlaps that of wanted signals, so that simple filtering cannot sufficiently enhance the signal to noise ratio. The present paper introduces the digital notch filtering to cope with the 50 Hz power line noise interference in the ECG signal. Modern biomedical amplifiers have a very high common mode rejection ratio. Nevertheless, recordings are often contaminated by residual power-line interference. Traditional analogue and digital filters are known to suppress ECG components near to the power-line frequency. FIR filter is used to remove 50 Hz power line noise interference from ECG signals(mixed with 50 Hz power line noise interference) , since it does not introduces phase distortion. A ECG signal (without noise) was mixed with constant 0.5mVp-p noise at different values of PLI frequencies 48,48.5,49,49.5,50,50.5 and 51 Hz, and processed by Band reject filters of stop band bandwidth of 48– 52Hz. The order of filter are taken as 500. In this paper the proposed filters were designed using Rectangular, Blackman, Hamming, Hann, Kaiser Window method to remove PLI from ECG. Simulation results are also shown. Performance of filters are analyzed by comparing MSE(mean square error) and SNR(signal to noise ratio) of output ECG signal. Key-Words: Rectangular, Hamming, Hann, Kaiser Window, power line noise interference(PLI) 1.Introduction: Electrocardiogram (ECG) is the record of the electrical potentials produced by the heart. The electrical wave is generated by depolarization and re-polarization of certain cells due to movement of Na+ and k+ ions in the blood. The ECG signal is typically in the range of 2 mV and requires a recording bandwidth of 0.1 to 120 Hz . The ECG is acquired by a non-invasive technique, i.e. placing electrodes at standardized locations on the skin of the patient. In clinical environment during acquisition, the ECG signal encounters various types of artifacts. The ones of primary interest are power line interference, external electromagnetic field interference, noise due to random body movements and respiration movements, electrode contact noise, electromyography (EMG) noise, and instrumentation noise. These noises degrade the signal quality, frequency resolution and strongly affect the morphology of ECG signal containing important information. It is essential to reduce disturbances in ECG signal and improve the accuracy and reliability for better diagnosis. Many methods have been implemented to remove the noise from noisy ECG signal. The basic method is to pass the signal through low pass, high pass, and notch filters. During past few years, various contributions have been made in literature regarding noise removal, beat detection and classification of ECG signal. Most of them use either time or frequency domain representation of the ECG waveforms. Many methods were proposed in the past for the removal of power line interference in the ECG. They can be categorized into two: non-adaptive and adaptive filtering. The non-adaptive filtering approach employs a sharp notch filter either in analog or digital form and has advantages of easy implementation and low cost. However its performance depends on the stability of the frequency of power line. Adaptive filtering on the other hand is able to remove the time-varying power line signal effectively. But it requires considerable computational power which is not suitable for the portable ECG devices. One of the ways to lower the power consumption is to utilize non-adaptive filters. 2.a Desirable feature: The amplifier should faithfully reproduce signals in its frequency range. A peak amplitude of an ECG signal is in the range of 1mv , so an ECG amplifier should typically have a gain of about 1000 in order to bring the peak signal into a range of 1v . CMRR of the order of 80 dB. to 120 dB. Imteyaz Ahmad et.al / International Journal on Computer Science and Engineering (IJCSE) ISSN : 0975-3397 Vol. 7 No.2 Feb 2015 13 2. b ECG signal and its acquisition: The ECG signal and heart rate reflects the cardiac health of human heart. : [a] The magnitude of the P wave never exceeds 2.5mV. [b] The PR interval is approximately between 0.12 and 0.2 Seconds. [c] The QRS wave lasts for 0.06-0.1 Seconds. [d]The QT interval is about 40% of the R wave to the next R wave when the body is not in the state of exercise. [e] The T wave's magnitude is usually 1/3-2/3 of the R wave's, and the T wave's interval is longer than that of the QRS's. Fig. 1: ECG waveform Any disorder in heart rate or rhythm or change in the morphological pattern of ECG signal is an indication of cardiac arrhythmia. It is detected and diagnosed by analysis of the recorded ECG waveform. The amplitude and duration of the P-QRS-T-U wave contains useful information about the nature of disease related to heart. • ECG signal is acquired from the surface of the body using disc type floating electrodes. For ECG data acquisition a quad-op amp consisting of four high speed BIFET op amp can be used. • The gain of instrumentation amplifier should be such as to give output of 1volt. The output of instrumentation amplifier is connected to band pass filter for frequency band of 0.05 Hz to 106 Hz. The noise signal produced due to patient movement is by passed to ground through right leg before amplification through instrumentation amplifier. 2.c Input ECG: ECG signal is taken from a hospital ECG database with sampling frequency of 500 Hz as shown below in Figure 2. A ECG signal (without noise) was mixed with constant 0.5 mVp-p 50 Hz interference shown in Figure 3. Imteyaz Ahmad et.al / International Journal on Computer Science and Engineering (IJCSE) ISSN : 0975-3397 Vol. 7 No.2 Feb 2015 14 0 1 2 3 4 5 6 7 8 9 10 -0.4 -0.2 0 0.2 0.4 0.6 0.8 1 1.2 1.4 Time(s) A m pl itu de (m V ) Pure ECG Fig. 2: Input ECG signal with sampling frequency of 500 Hz 0 1 2 3 4 5 6 7 8 9 10 -1 -0.5 0 0.5 1 1.5 2
منابع مشابه
Design and implementation of Digital FIR Equiripple Notch Filter on ECG Signal for removal of Power line Interference
Filtering of power line interference is very meaningful in the measurement of biomedical events recording, particularly in the case of recording signals as weak as the ECG. The available filters for power line interference either need a reference channel or regard the frequency as fixed 50/60Hz. Methods of noise reduction have decisive influence on performance of all electro-cardio-graphic (ECG...
متن کاملReview on Power Line Interference Removal from ECG Signal Using Adaptive and Error Filter
An ECG signal is basically an index of the functionality of the heart. For example, a physician can detect arrhythmia by studying abnormalities in the ECG signal. Since very fine features present in an ECG signal may convey important information, it is important to have the signal as clean as possible. Power line interference may be significant in electrocardiography. Often, a proper recording ...
متن کاملSurvey of Wearable Sensors with Comparative Study of Noise Reduction ECG Filters
Wearable sensors are the major part of Wireless Body Area Networks (WBANs) for provision of health care services and physical activity monitoring. In this paper, a brief survey of different types of wearable sensors presented along with sensor placement. Designing of wearable sensors for ECG and Blood pressure also discussed. Comparative study of FIR and IIR noise reduction ECG filters discusse...
متن کاملNoise Removal from Surface Respiratory EMG Signal
The aim of this study was to remove the two principal noises which disturb the surface electromyography signal (Diaphragm). These signals are the electrocardiogram ECG artefact and the power line interference artefact. The algorithm proposed focuses on a new Lean Mean Square (LMS) Widrow adaptive structure. These structures require a reference signal that is correlated with the noise contaminat...
متن کاملECG Signal Denoising Using Wavelet Thresholding Techniques in Human Stress Assessment
In recent years, Electrocardiogram (ECG) plays an imperative role in heart disease diagnostics, Human Computer Interface (HCI), stress and emotional states assessment, etc. In general, ECG signals affected by noises such as baseline wandering, power line interference, electromagnetic interference, and high frequency noises during data acquisition. In order to retain the ECG signal morphology, s...
متن کامل