Delayed Presentation of a Giant Ascending Aortic Aneurysm following Aortic Valve Replacement
نویسندگان
چکیده
Giant ascending aortic aneurysm formation following aortic valve replacement is rare. A 28-year-old man who underwent aortic valve replacement with a prosthetic valve for aortic regurgitation secondary to congenital bicuspid aortic valve about 10 years ago was diagnosed with a giant ascending aortic aneurysm about 16 cm in diameter in follow-up. The aneurysm was resected leaving the functional old mechanical prosthesis in place and implanted a 34-mm Hemashield woven graft, associated with the left and right coronary artery button implantation. Histological findings of the aortic aneurysm wall showed cystic medial necrosis. The postoperative course was uneventful and postoperative examination demonstrated good surgical results.
منابع مشابه
Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm
Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملA Giant Dissecting Aneurysm of Ascending Aorta Following Aortic Valve Replacement
Ascending aortic dissection and aneurysm are rare but life-threatening complications after aortic valve replacement. Preoperative evaluation of risk factors such as aortic diameter, structural features of aortic wall, and associated diseases may decrease complication rate. We herein present analysis of risk factors of proximal aortic events following aortic valve replacement based on patient wi...
متن کاملGiant Aortic Pseudoaneurysm with Stanford Type A Aortic Dissection after Aortic Valve Replacement
Giant pseudoaneurysm of the ascending aorta is a rare but dreadful complication occurring several months or years after aortic surgery. Thoracic aortic aneurysms tend to be asymptomatic and were previously often diagnosed only after a complication such as dissection or rupture. We present a rare case of giant ascending aneurysm with Stanford type A aortic dissection occurring 6 years after aort...
متن کاملImages in emergency medicine: giant ascending aortic aneurysm dissection with hemopericardium.
BACKGROUND Acute chest pain represents a common presentation at emergency department. Aortic dissection in young patients, however, is fortunately rare. METHODS We report a case of giant ascending aortic aneurysm with Stanford type A aortic dissection in an otherwise well 22-year-old male patient. Operative aortic valve and root replacement was undertaken with favourable outcome. RESULTS Hi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2009 شماره
صفحات -
تاریخ انتشار 2009