OBJECTIVES To determine whether the biplane area-length method can be used for the evaluation of left atrial volumes and ejection fraction with cardiovascular magnetic resonance imaging (CMR) by TrueFISP in normal subjects and patients with atrial fibrillation. BACKGROUND Atrial fibrillation is the most common arrhythmia in elderly patients. Left atrial size and volumes play an important role in predicting short and long-term success after cardioversion. METHODS Fifteen healthy subjects (mean age 65.6+/-6.4 years) and 18 patients (mean age 67.2+/-8.8 years) with atrial fibrillation were examined by CMR (Magnetom, Siemens, Erlangen, Germany). Images were acquired by TrueFISP using the horizontal and vertical long-axis plane to measure left atrial end-diastolic and end-systolic areas and longitudinal dimensions. Volumes were determined with commercially available software. Left atrial end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were determined by the biplane area-length method and compared to findings obtained by the standard short-axis method. Images were acquired and analyzed a second time in the patients with atrial fibrillation. RESULTS There was no difference in age between men and women (p=0.147) and healthy subjects and patients (p=0.128) included in the study. EDV and ESV were significantly higher and SV and EF significantly lower in patients with atrial fibrillation than in healthy subjects (p < or = 0.009), regardless of the method used. The values obtained for EDV and ESV by the biplane area-length method were significantly higher in both healthy subjects (p<0.001) and patients with atrial fibrillation (p<0.001) than those obtained by the standard short-axis approach, whereas SV (p> or = 0.057) and EF (p> or = 0.118) did not differ significantly. In the second investigation in patients with atrial fibrillation, ESV, SV, and EF did not differ significantly between the two methods (p> or =0.481). Assessment of interobserver variability revealed good agreement in the findings of the two observers, both in normal sinus rhythm and atrial fibrillation (overall variability 0.8+/-6.5%). CONCLUSIONS The biplane area-length method can be used in CMR images obtained by TrueFISP to assess left atrial volumes and ejection fraction in normal subjects and patients with varying cardiac cycle length, as in atrial fibrillation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of left atrial volumes at 1.5 Tesla and 3 Tesla using FLASH and SSFP cine imaging.

PURPOSE To investigate left atrial volumes and function and their variability in healthy volunteers using steady state free precession (SSFP) and fast low angle shot (FLASH) sequences at both 1.5 and 3 T using both the short-axis and biplane area-length methods. MATERIALS AND METHODS Ten healthy volunteers underwent CMR at both 1.5 and 3 Tesla. The biplane area-length method utilized volumes ...

متن کامل

Cardiovascular magnetic resonance assessment of left atrial volumes and function in patients with persistent atrial fibrillation before and after ablation therapy

Methods A Siemens scanner (Avanto, 1.5T) was used to study 13 patients (mean age 65 ± 9, 4 females and 9 males) with persistent AF before and 3 months after ablation therapy. Images of the LA were acquired in the two-chamber and four-chamber orientation using a breath-hold ECG-gated steady state free precession cine sequence. Biplane arealength method was used to measure the LA end-systolic (ES...

متن کامل

Single and biplane TrueFISP cardiovascular magnetic resonance for rapid evaluation of left ventricular volumes and ejection fraction.

INTRODUCTION Cardiovascular magnetic resonance (CMR) allows very accurate, but time-consuming, volume assessment by the short-axis slice summation technique. The single and biplane methods of volume assessment are used less, partly because FLASH cine imaging provides poor blood-myocardium contrast in long-axis views. TrueFISP gives excellent blood-myocardium contrast, even in patients with hear...

متن کامل

Left atrial volume quantification using cardiac MRI in atrial fibrillation: comparison of the Simpson's method with biplane area-length, ellipse, and three-dimensional methods.

PURPOSE Left atrial volume is an important predictor of future arrhythmias, and it can be assessed by several different methods. Simpson's method is well accepted as a reference standard, although no standardization exists for cardiac magnetic resonance (CMR). We aimed to compare the estimations of left atrial volumes obtained by the Simpson's method with three other methods. MATERIALS AND ME...

متن کامل

Left atrial volume is associated with mid-wall fibrosis in Dilated Cardiomyopathy

Introduction Left atrial (LA) size as assessed by echocardiography has been shown to have prognostic value in patients with dilated cardiomyopathy (DCM). More recently cardiac magnetic resonance (CMR) imaging studies have reported that the presence of left ventricular mid-wall late gadolinium enhancement (LGE), a marker of myocardial fibrosis, also predicts adverse outcome in DCM. The biplane a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 2004