Evaluation of the ΔV 4D CT ventilation calculation method using in vivo xenon CT ventilation data and comparison to other methods
نویسندگان
چکیده
Ventilation distribution calculation using 4D CT has shown promising potential in several clinical applications. This study evaluated the direct geometric ventilation calculation method, namely the ΔV method, with xenon-enhanced CT (XeCT) ventilation data from four sheep, and compared it with two other published meth-ods, the Jacobian and the Hounsfield unit (HU) methods. Spearman correlation coefficient (SCC) and Dice similarity coefficient (DSC) were used for the evaluation and comparison. The average SCC with one standard deviation was 0.44 ± 0.13 with a range between 0.29 and 0.61 between the XeCT and ΔV ventilation distributions. The average DSC value for lower 30% ventilation volumes between the XeCT and ΔV ventilation distributions was 0.55 ± 0.07 with a range between 0.48 and 0.63. Ventilation difference introduced by deformable image registration errors improved with smoothing. In conclusion, ventilation distributions generated using ΔV-4D CT and deformable image registration are in reasonably agreement with the in vivo XeCT measured ventilation distribution.
منابع مشابه
Dependence of ventilation image derived from 4D CT on deformable image registration and ventilation algorithms
Ventilation imaging using 4D CT is a convenient and low-cost functional imaging methodology which might be of value in radiotherapy treatment planning to spare functional lung volumes. Deformable image registration (DIR) is needed to calculate ventilation imaging from 4D CT. This study investigates the dependence of calculated ventilation on DIR methods and ventilation algorithms. DIR of the no...
متن کاملEvaluation of Four-dimensional (4D) Computed Tomography (CT) Pulmonary Ventilation Imaging by Comparison with Single Photon Emission Computed Tomography (SPECT) Scans for a Lung Cancer Patient
The goal of this study was to present a method for physiologic validation and show results for a comparison of the 4D-CT ventilation and SPECT ventilation or perfusion. A 4D-CT and a SPECT ventilation/perfusion (V/Q) (VSPECT and QSPECT) scans were acquired for a lung cancer patient. Two 4D-CT ventilation images were created using two metrics: Hounsfield unit (HU)-change (V4D-CT) and Jacobian de...
متن کاملEffects of quantum noise in 4D-CT on deformable image registration and derived ventilation data.
Quantum noise is common in CT images and is a persistent problem in accurate ventilation imaging using 4D-CT and deformable image registration (DIR). This study focuses on the effects of noise in 4D-CT on DIR and thereby derived ventilation data. A total of six sets of 4D-CT data with landmarks delineated in different phases, called point-validated pixel-based breathing thorax models (POPI), we...
متن کاملPatient absorbed dose comparison in CT and Stereoradiography (EOS) imaging during lower limb torsion evaluation using in-vivo and in-vitro dosimetry methods
Introduction: Accurate evaluation of femoral and tibial torsion is essential for children or adult with legs deformity, becuse incorrect legs morphogenesis can lead to pathological situation. CT scan is commonly used for the measurement of skeletal bone parameters. But, disability in imaging from standing and sitting posture and absorb dose of patients are deficits of this meth...
متن کاملNormalization of Ventilation Data from 4D-CT to Facilitate Comparison between Datasets Acquired at Different Times
PURPOSE The 4D-CT data used for comparing a patient's ventilation distributions before and after lung radiotherapy are acquired at different times. As a result, an additional variable--the tidal volume (TV)--can alter the results. Therefore, in this paper we propose to normalize the ventilation to the same TV to eliminate that uncertainty. METHODS Absolute ventilation (AV) data were generated...