An Innovative TCR Compensator for Closed Loop Reactive Power Compensation of Dynamic Loads

نویسندگان

  • Irfan I. Mujawar
  • Isak I. Mujawar
  • Devendra L. Raokhande
چکیده

Topology for closed loop reactive power compensation suitable for dynamic loads using TCR is presented. Firing angle range of TCR is selected in such a way to keep the harmonic content at a minimum level. Simulation results show that the proposed scheme can achieve reactive power compensation in less than a half cycle and the harmonics contents of source are maintained at insignificant levels due to delta connection of TCR and appropriate firing angle range selection of TCR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TBSC-TCR Compensator Simulation: A New Approach in Closed Loop Reactive Power Compensation of Dynamic Loads

Topology for reactive power compensation of dynamic load in closed loop is presented. The scheme consists of Thyristor Binary Switched Capacitor (TBSC) banks and a Thyristor Controlled Reactor (TCR). TBSC is based on a chain of Thyristor Switched Capacitor (TSC) banks arranged in binary sequential manner. TCR capacity is chosen to be smallest of TBSC step size. A transient free switching of TBS...

متن کامل

A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...

متن کامل

Enhancement of Power Quality using Tapped Inductor FC-TCR

This Paper deals with digital simulation of FC-TCR, which can enhance the Power Quality of a power system. Reactive power is controlled by using tapped inductor system. This system reduces THD in the line current. Smooth variation of reactive power can be obtained by varying the firing angle of TCR. This circuit eliminates switching transients and improves the life of the capacitors. The simula...

متن کامل

An Innovative Transient Free Adaptive SVC in Stepless Mode of Control

Electrical distribution systems are incurring large losses as the loads are wide spread, inadequate reactive power compensation facilities and their improper control. A comprehensive static VAR compensator consisting of capacitor bank in five binary sequential steps in conjunction with a thyristor controlled reactor of smallest step size is employed in the investigative work. The work deals wit...

متن کامل

A Comparison between SVC and STATCOM in Flicker Mitigation of Electric Arc Furnace using Practical Recorded Data

Electric arc furnace (EAF) is one of the largest loads in electric power systems. It is highly time varying and nonlinear. Its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. On the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in EAF. To this end Flexible AC Transmission Systems (FACTS) techn...