Inserting the distal screws in a locked femoral nail.
نویسندگان
چکیده
We describe a simple method of inserting the distal screws in a locked femoral nail. The method requires no aiming device and no assistant. The only equipment needed is a 3 mm Kirschner wire and an air drill.
منابع مشابه
Intramedullary nails with distal interlocking screws locked to the nail may have higher fatigue strength in comminuted supracon
Figure 2. Specimen mounted on the MTS. Intramedullary nails with distal interlocking screws locked to the nail may have higher fatigue strength in comminuted supracondylar femur fractures McDonald, E;, Fischer, J; Bartlett, T; Buckley, J.M; Pekmezci, M, +Kandemir, U +Biomechanical Testing Facility, UCSF/SFGH Orthopaedic Trauma, University of California at San Francisco, San Francisco, CA, USA D...
متن کاملBlocking screws for the treatment of distal femur fractures.
Intramedullary nailing is one of the most convenient biological options for treating distal femoral fractures. Because the distal medulla of the femur is wider than the middle diaphysis and intramedullary nails cannot completely fill the intramedullary canal, intramedullary nailing of distal femoral fractures can be difficult when trying to obtain adequate reduction. Some different methods exis...
متن کاملAnatomic Structures at Risk When Utilizing an Intramedullary Nail for Distal Fibular Fractures: A Cadaveric Study.
BACKGROUND Retrograde intramedullary fibular nail fixation is being utilized with increasing frequency, particularly in patients at higher risk of wound complications. The purpose of this anatomic study was to assess the relative risk to nearby anatomic structures when implanting a contemporary retrograde locked intramedullary fibular nail. METHODS Ten human cadaveric lower extremities were i...
متن کاملNew Technique: A Novel Femoral Derotation Osteotomy for Malrotation following Intramedullary Nailing
A 19-year-old female patient sustained a closed spiral midshaft femoral fracture and subsequently underwent femoral intramedullary nail insertion. At followup she complained of difficulty in walking and was found to have a unilateral in-toeing gait. CT imaging revealed 30 degrees of internal rotation at the fracture site, which had healed. A circumferential osteotomy was performed distal to the...
متن کاملDistal locking in femoral intramedullary nailing system: Is one cross screw sufficient?
Introduction: The indications for intramedullary nail fixation of fractures of the femoral shaft have been greatly expanded by techniques of interlocking nailing. However, distal locking screw fixation remains the most technically demanding and problematic portion of the procedure and maybe responsible for as much as one-half of the exposure of the surgeon’s hands to radiation during the proced...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 73 4 شماره
صفحات -
تاریخ انتشار 1991