Effect of displacement of fractures of the greater tuberosity on the mechanics of the shoulder.

نویسندگان

  • C M Bono
  • R Renard
  • R G Levine
  • A S Levy
چکیده

Using a dynamic biomechanical model of malunion of the shoulder, we have determined the change in deltoid force required for abduction with various combinations of superior and posterior displacement of fractures of the greater tuberosity of the humerus. We tested eight fresh human cadaver shoulders in a dynamic shoulder-testing apparatus during cycles of glenohumeral abduction from 0 degrees to 90 degrees. The greater tuberosities were osteotomised and stabilised to represent malunion with combinations of superior and posterior displacements of 1 cm and less. The peak force was measured for each displacement in each specimen and statistically compared with values of no displacement using a repeated-measures analysis of variance. The abduction force was significantly increased by 16% (p = 0.006) and 27% (p = 0.0001) by superior displacements of 0.5 cm and 1 cm, respectively, while combined superior and posterior displacement of 1 cm gave an increase in force of 29% (p = 0.001). While treatment criteria for acceptable residual displacement of the greater tuberosity are widely used, there is little information on the direct biomechanical effects of displacement on shoulder mechanics. Although the results of conservative treatment are influenced by a number of factors, including associated injuries, rehabilitation and the pre-existing function of the shoulder, our data suggest that small amounts of residual displacement may alter the balance of forces required to elevate the arm at the glenohumeral joint.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative 3-dimensional Computerized Tomography Modeling of Isolated Greater Tuberosity Fractures with and without Shoulder Dislocation

Background: The aim of this study was to assess differences in fracture morphology and displacement betweenisolated greater tuberosity (GT) fractures (i.e. fractures of the greater tuberosity without other fractures of the proximalhumerus) with and without shoulder dislocation utilizing quantitative 3-dimensional CT imaging.Methods: Thirty-four CT-scans of isolated greater tuberosity fractures ...

متن کامل

Long-term Results, Functional Outcomes and Complications after Open Reduction and Internal Fixation of Neglected and Displaced Greater Tuberosity of Humerus Fractures

  Background: Humerus fractures include 5% to 8% of total fractures. Non-union and delayed union of GT (GT) fractures is uncommon; however they present a challenge to the orthopedic surgeons. Significant controversy surrounds optimal treatment of neglected fractures. The purpose of this article was to perform a comparative study to evaluate the outcomes of open reduction and internal fixatio...

متن کامل

The pattern of the fracture and displacement of the fragments predict the outcome in proximal humeral fractures.

Our aim was to determine the effect of the initial pattern of fracture and the displacement of fragments on the outcome of proximal humeral fractures treated conservatively. We followed 93 consecutive patients prospectively for one year. Final movement and strength were compared with those of the contralateral side. The final American Shoulder and Elbow Society score and the Disabilities of Arm...

متن کامل

The definition of recurrent shoulder dislocation in tramadol induced seizure patients

Background: Prevalence of recurrent shoulder dislocation in patients taking tramadol has not been studiedyet so, this study aims to study the recurrent shoulder dislocation following tramadol induced seizure. Methods: In this cross-sectional study, 205 patients with recurrent shoulder dislocation complaints (2 or more) referred to Shafa Orthopedic and Iranmehr hospitals Tehran, Iran, from Oc...

متن کامل

AO X-shaped midfoot locking plate to treat displaced isolated greater tuberosity fractures.

Although various implants exist for 3- and 4-part fractures, few implants are appropriate for isolated greater tuberosity fractures. This retrospective study evaluated the efficacy of AO X-shaped midfoot locking plates for greater tuberosity fractures. Between May 2008 and September 2009, nineteen patients with displaced greater tuberosity fractures were treated with open reduction and internal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 83 7  شماره 

صفحات  -

تاریخ انتشار 2001