[Measuring the refractive power of customized soft contact lenses].
نویسندگان
چکیده
PURPOSE Soft contact lenses with spherical base curves have been used for many years. The computation of the refractive powers of these lenses is easy, requiring only that one uses the lens maker equation for thick lenses. Nevertheless, for customized contact lenses, there is yet no reliable method for measuring the higher order optical aberrations. In this study we have developed in the Center for Visual Sciences of the University of Rochester an optical apparatus that allows for precise measurement of low and high order aberrations of customized soft contact lenses. METHODS An optical apparatus was mounted on a conventional optical bench. This apparatus consists of a wet cell where the contact lenses are placed, a series of relay lenses, mirrors, beam splitters, and a Hartmann-Shack sensor. Bausch & Lomb manufactured the lenses used in this study. RESULTS The root mean square error (RMSE) of the instrument was 0.04 microns. Given that the RMSE of the customized lens is between 4 and 6 microns, i.e., the precision of the instrument is approximately 1%. This precision is more than sufficient for the type of measurements necessary for manufacturing customized contact lenses. CONCLUSION The instrument developed is extremely precise for measuring high order aberrations--up to the 10th order Zernike polynomials, that is, up to the 66th term. This technology is important for the development of new methods of optical corrections for patients that usually do not adapt to normal sphere-cylinder spectacles or that cannot undergo refractive surgery, such as those which have keratoconus, for example.
منابع مشابه
Fabricating customized hydrogel contact lens
Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fab...
متن کاملGeneration of Higher Order Aberrations with Soft Contact Lens by Excimer Laser Ablation
Although the human eye has a relatively simple optical system, it is not perfect. It has been well known that the human eye suffers from the wavefront aberration that includes both lower (defocus and astigmatism) and higher order aberrations. The lower order aberration has been effectively corrected with conventional ophthalmic lenses such as spectacles and contact lenses. However, it is more c...
متن کاملPeripheral refraction with different designs of progressive soft contact lenses in myopes
Aim: The purpose of this study was to compare the changes in relative peripheral refractive error produced by two different designs of progressive soft contact lenses in myopic schoolchildren. Methods: Twenty-seven myopic schoolchildren age between 13 to 15 years were included in this study. The measurements of central and peripheral refraction were made using a Grand-Seiko WR-5100K open-field ...
متن کاملMeasurement of wave-front aberration in soft contact lenses by use of a Shack-Hartmann wave-front sensor.
Lower- and higher-order wave-front aberrations of soft contact lenses were accurately measured with a Shack-Hartmann wave-front sensor. The soft contact lenses were placed in a wet cell filled with lens solution to prevent surface deformation and desiccation during measurements. Aberration measurements of conventional toric and multifocal soft contact lenses and a customized soft contact lens h...
متن کاملVisual performance after reduced blinking in eyes with soft contact lenses or after LASIK.
PURPOSE To evaluate visual performance during concentrated visual work in patients wearing soft contact lenses or after LASIK. METHODS Thirty-one eyes of 17 patients who had worn soft contact lenses before LASIK were examined by the following tests immediately and 10 seconds after eye opening: 1) functional visual acuity, which is defined as visual acuity measured after prolonged eye opening ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de oftalmologia
دوره 70 1 شماره
صفحات -
تاریخ انتشار 2007