Sub-micron silica diaphragm-based fiber-tip Fabry-Perot interferometer for pressure measurement.

نویسندگان

  • Changrui Liao
  • Shen Liu
  • Lei Xu
  • Chao Wang
  • Yiping Wang
  • Zhengyong Li
  • Qiao Wang
  • D N Wang
چکیده

We demonstrate a sub-micron silica diaphragm-based fiber-tip Fabry-Perot interferometer for pressure sensing applications. The thinnest silica diaphragm, with a thickness of ∼320  nm, has been achieved by use of an improved electrical arc discharge technique. Such a sub-micron silica diaphragm breaks the sensitivity limitation imposed by traditional all-silica Fabry-Perot interferometric pressure sensors and, as a result, a high pressure sensitivity of ∼1036  pm/MPa at 1550 nm and a low temperature cross-sensitivity of ∼960  Pa/°C are achieved when a silica diaphragm of ∼500  nm in thickness is used. Moreover, the all-silica spherical structure enhanced the mechanical strength of the micro-cavity sensor, making it suitable for high sensitivity pressure sensing in harsh environments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-sensitivity fiber-tip pressure sensor with graphene diaphragm.

A miniature fiber-tip pressure sensor was built by using an extremely thin graphene film as the diaphragm. The graphene also acts as a light reflector, which, in conjunction with the reflection at the fiber end-air interface, forms a low finesse Fabry-Perot interferometer. The graphene based sensor demonstrated pressure sensitivity over 39.4 nm/kPa with a diaphragm diameter of 25 μm. The use of...

متن کامل

Microfluidic refractive index sensor based on an all-silica in-line Fabry-Perot interferometer fabricated with microstructured fibers.

We report a microfluidic fiber-optic refractive index (RI) sensor based on an in-line Fabry-Perot (FP) interferometer, which is formed by a silica tube sandwiched by two microstructured fibers (MFs). The sensor reported here can be fabricated at low cost, possess a robust structure, and has microfluidic capability. The micro-sized holes in the MFs naturally function as microfluidic channels thr...

متن کامل

High-Temperature Sensor Based on Fabry-Perot Interferometer in Microfiber Tip

A miniaturized tip Fabry-Perot interferometer (tip-FPI) is proposed for high-temperature sensing. It is simply fabricated for the first time by splicing a short length of microfiber (MF) to the cleaved end of a standard single mode fiber (SMF) with precise control of the relative cross section position. Such a MF acts as a Fabry-Perot (FP) cavity and serves as a tip sensor. A change in temperat...

متن کامل

Chitosan Layer Fabry - Perot Interferometer - Based Optical Fiber Sensor for Cadmium Ion Detection

Optical sensors based on Fabry-Perot interferometer to detect cadmium ions is proposed. The sensor was fabricated by coating the tip of the optical fiber by chitosan. The two chitosan surfaces serve as mirrors which form a Fabry-Perot interferometer. The characterization results indicate that the sensor has a linear response with sensitivity of 0.0884 dBm/ppm with a correlation factor of 0.9665...

متن کامل

Simultaneous measurement of pressure and temperature by employing Fabry-Perot interferometer based on pendant polymer droplet.

We investigated a novel and ultracompact polymer-capped Fabry-Perot interferometer, which is based on a polymer capped on the endface of a single mode fiber (SMF). The proposed Fabry-Perot interferometer has advantages of easy fabrication, low cost, and high sensitivity. The variation of the Fabry-Perot cavity length can be easily controlled by using the motors of a normal arc fusion splicer. M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 39 10  شماره 

صفحات  -

تاریخ انتشار 2014