Spatial Characterization of Electrogram Morphology from Transmural Recordings in the Intact Normal Heart
نویسندگان
چکیده
PURPOSE Unipolar (UE) and bipolar electrograms (BE) are utilized to identify arrhythmogenic substrate. We quantified the effect of increasing distance from the source of propagation on local electrogram amplitude; and determined if transmural electrophysiological gradients exist with respect to propagation and stimulation depth. METHODS Mapping was performed on 5 sheep. Deployment of >50 quadripolar transmural needles in the LV were located in Cartesian space using Ensite. Contact electrograms from all needles were recorded during multisite bipolar pacing from epicardial then endocardial electrodes. Analysis was performed to determine stimulus distance to local activation time, peak negative amplitude (V-P), and peak-peak amplitude (VP-P) for (1) unfiltered UE, and (2) unfiltered and 30 Hz high-pass filtered BEs. Each sheep was analysed using repeated ANOVA. RESULTS Increasing distance from the pacing sites led to significant (p<0.01) attenuation of UEs (V-P = 7.0±0.5%; VP-P = 5.4±0.3% per cm). Attenuation of BE with distance was insignificant (Vp-p unfiltered = 2.2±0.5%; filtered = 1.7±1.4% per cm). Independent of pacing depth, significant (p<0.01) transmural electrophysiological gradients were observed, with highest amplitude occurring at epicardial layers for UE and endocardial layers for BE. Furthermore, during pacing, propagation was earlier at the epicardium than endocardial layer by 1.6±2.0 ms (UE) and 1.4±2.8 ms (BE) (all p>0.01) during endocardial stimulation, and 2.3±2.4 ms (UE) and 1.8±3.7 ms (BE) during epicardal stimulation (all p<0.01). CONCLUSIONS Electrogram amplitude is inversely proportional to propagation distance for unipolar modalities only, which affected V-P>VP-P. Conduction propagates preferentially via the epicardium during stimulation and is believed to contribute to a transmural amplitude gradient.
منابع مشابه
Elimination of the negative component of the unipolar atrial electrogram as an in vivo marker of transmural lesion creation: acute study in canines.
BACKGROUND It has been experimentally shown that elimination of the negative component of the unipolar atrial electrogram (R morphology completion) during radiofrequency applications reflects transmural lesions creation. Subsequently, it has been clinically suggested that such a transmurality can be either irreversible or reversible. The present study is aimed to determine, at the histological ...
متن کاملLocal transmural action potential gradients are absent in the isolated, intact dog heart but present in the corresponding coronary‐perfused wedge
The left ventricular (LV) coronary-perfused canine wedge preparation is a model commonly used for studying cardiac repolarization. In wedge studies, transmembrane potentials typically are recorded; whereas, extracellular electrical recordings are commonly used in intact hearts. We compared electrically measured activation recovery interval (ARI) patterns in the intact heart with those recorded ...
متن کامل3D Characterization of Uniaxial Compressive Strength of Transversely-Isotropic Intact Rocks
The uniaxial compressive strength (UCS) of intact rocks is one of the key parameters in the course of site characterizations. The isotropy/anisotropy condition of the UCS of intact rocks is dependent on the internal structure of the rocks. The rocks with a random grain structure exhibit an isotropic behavior. However, the rocks with a linear/planar grain structure generally behave transversely-...
متن کاملIdentification of ventricular tachycardia with use of the morphology of the endocardial electrogram.
Currently available antitachycardia devices rely primarily on timing information to define abnormal rhythms. It would be useful to have more specific means of automatically identifying pathologic tachycardias. Using unfiltered (0.04 to 500 Hz bandpass) recordings made during electrophysiologic testing in 10 patients with ventricular tachycardia (VT), we studied the differences in electrogram mo...
متن کاملA PCA/ICA based Fetal ECG Extraction from Mother Abdominal Recordings by Means of a Novel Data-driven Approach to Fetal ECG Quality Assessment
Background: Fetal electrocardiography is a developing field that provides valuable information on the fetal health during pregnancy. By early diagnosis and treatment of fetal heart problems, more survival chance is given to the infant.Objective: Here, we extract fetal ECG from maternal abdominal recordings and detect R-peaks in order to recognize fetal heart rate. On the next step, we find a be...
متن کامل