A new, specular reflection-based, precorneal tear film stability measurement technique in a rabbit model: viscoelastic increases tear film stability.

نویسندگان

  • Derek Nankivil
  • Alex Gonzalez
  • Esdras Arrieta
  • Cornelis Rowaan
  • Mariela C Aguilar
  • Krystal Sotolongo
  • Florence A Cabot
  • Sonia H Yoo
  • Jean-Marie A Parel
چکیده

PURPOSE To develop a safe, noninvasive, noncontact, continuous in vivo method to measure the dehydration rate of the precorneal tear film and to compare the effectiveness of a viscoelastic agent in maintaining the precorneal tear film to that of a balanced salt solution. METHODS Software was designed to analyze the corneal reflection produced by the operating microscope's coaxial illumination. The software characterized the shape of the reflection, which became distorted as the precorneal tear film evaporated; characterization was accomplished by fitting an ellipse to the reflection and measuring its projected surface area. Balanced salt solution Plus (BSS+) and a 2% hydroxypropylmethylcellulose viscoelastic were used as the test agents. The tear film evaporation rate was characterized and compared over a period of 20 minutes in 20 eyes from 10 New Zealand white rabbits. RESULTS The ellipse axes ratio and surface area were found to decrease initially after each application of either viscoelastic or BSS+ and then to increase linearly as the tear film began to evaporate (P < 0.001) for eyes treated with BSS+ only. Eyes treated with BSS+ required 7.5 ± 2.7 applications to maintain sufficient corneal hydration during the 20-minute test period, whereas eyes treated with viscoelastic required 1.4 ± 0.5 applications. The rates of evaporation differed significantly (P < 0.043) between viscoelastic and BSS+. CONCLUSIONS The shape and surface area of the corneal reflection are strongly correlated with the state of the tear film. Rabbits' corneas treated with viscoelastic remained hydrated significantly longer than corneas treated with BSS+.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of novel amphipathic block copolymers on stabilization of the rat tear film.

PURPOSE To determine whether various novel amphipathic polymers could be used to stabilize the tear film of the rat. The rheologic properties of these polymers were examined to investigate whether particular structural or physical characteristics improve the stability of the tear film. METHODS Amphipathic polymers or particular phospholipids were mixed with a test solution of tears and saline...

متن کامل

Effect of benzalkonium chloride on the stability of the precorneal tear film in rabbit and man.

Benzalkonium chloride, a surface-active preservative commonly used in eyedrop preparations, has been shown to hasten the drying of the precorneal tear film. In the rabbit, 0.01 per cent benzalkonium (the concentration usually employed as a preservative) shortened the time required for the appearance of dry spots on the corneal surface by a factor of about four. In man, an approximately twofold ...

متن کامل

Non-invasive in vivo measurement of the tear film using spatial autocorrelation in a live mammal model

Tear film stability and its interaction with the corneal surface play an important role in maintaining ocular surface integrity and quality of vision. We present a non-invasive technique to quantify the pre-corneal tear film thickness. A cMOS camera is used to record the interference pattern produced by the reflections from multiple layers of the tear film Principles of spatial autocorrelation ...

متن کامل

Concerns about peer review process.

I am concerned about the lack of proper scrutiny during the peer review process. Although I exemplify it in one paper in a field in which I have some expertise, I believe that this single case shows severe failure of peer review, and it should not have happened. I refer to the article by Nankivil et al. in the latest edition of IOVS Vol 55 No. 7. There seems to be no evidence of scientific rigo...

متن کامل

Effect of water-in-oil microemulsions and lamellar liquid crystalline systems on the precorneal tear film of albino New Zealand rabbits

The aim of this study is to investigate the effect of phase transition water-in-oil (w/o) microemulsions (ME) and liquid crystalline systems (LC) on the precorneal tear film (PCTF). The study used six albino NZ rabbits and monitored the integrity and stability of the PCTF before and after instillation of test formulations. The effects were evaluated by assessment of the PCTF lipid layer using i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 55 7  شماره 

صفحات  -

تاریخ انتشار 2014