Total body irradiation dose optimization based on radiological depth
نویسندگان
چکیده
We have previously demonstrated the use of Eclipse fluence optimization to define aperture sizes for a novel aperture modulated translating bed total body irradiation (TBI) technique. The purposes of the present study were to identify, characterize, and correct for sources of error inherent in our previous fluence optimization technique, and to develop a clinically viable fluence optimization module for the translating bed TBI technique. Aperture modulated TBI is delivered by translating the patient at constant speed on a custom bed under a modulated radiation beam. The patient is then turned from supine to prone and the process repeated, resulting in an AP-PA treatment. Radiological depths were calculated along divergent ray lines through individual CT slices of a RANDO phantom. Beam apertures, defined using a dynamic multileaf collimator (DMLC), were generated using calculated radiological depths and calibration factors that relate fluence to aperture size in a dynamic environment. These apertures were defined every 9 mm along the phantom superior-inferior axis. The calculated beam apertures were further modified to account for scatter within the patient. For dose calculation purposes the individual MLC files were imported into Eclipse. For treatment delivery, dynamic MLC files for both AP and PA beams were generated and delivered dynamically. Dose homogeneity in the head and neck region of the RANDO phantom was within ± 4% of the prescribed dose with this novel technique compared to -5% to +7% with our previous aperture modulated technique based on Eclipse fluence optimization. Fluence optimization and beam aperture calculation using the new technique offers a ten-fold reduction in planning time and significantly reduces the likelihood of user error during the planning process. In conclusion, a clinically viable aperture modulated translating bed TBI technique that employs dynamically shaped MLC-defined beam apertures based on radiological depth calculations, has been developed.
منابع مشابه
Diode calibration for dose determination in total body irradiation
Background: Total Body Irradiation (TBI) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under TBI treatment. Diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. The aim of this study was to describe the measurements made to calib...
متن کاملEvaluation of dose uniformity in total body irradiation (TBI) technique in parallel-opposed anterior/posterior geometry using Varian Clinac 2100C/D linear accelerator
Background: Total body irradiation (TBI) is a technique that is commonly used as a part of the patient conditioning regimen before the bone marrow transplant (BMT). The purpose of this study is to introduce and implement a reasonable TBI technique on the human-like phantom in Imam Khomeini Hospital in Tehran. Methods: The present experimental study was conducted from October 2016 to November 2...
متن کاملReview of techniques for improving the uniformity of dose distribution in total body irradiation (TBI) with parallel – opposed anterior and posterior geometry
Total body irradiation (TBI) is a kind of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression before bone marrow transplantation. As recommended by AAPM dose distribution uniformity in TBI is very important and dose variation must be within ±10% of prescription dose. Patients treatment geometry for TBI techniques fall into two co...
متن کاملImpact of Prolonged Fraction Delivery Time Modelling Stereotactic Body Radiation Therapy with High Dose Hypofractionation on the Killing of Cultured ACHN Renal Cell Carcinoma Cell Line
Introduction: Stereotactic body radiotherapy delivers hypofractionated irradiation with high dose per fraction through complex treatment techniques. The increased complexity leads to longer dose delivery times for each fraction. The purpose of this study is to investigate the impact of prolonged fraction delivery time with high-dose hypofractionation on the killing of cultured ACHN cells.Method...
متن کاملPhysical dose reconstruction in case of radiological accidents : an asset for the victims ’ management
In most cases of radiological accidents caused by an external source, the irradiation is heterogeneous, even for a whole body irradiation. Therefore, more than a whole body dose, estimating the dose distribution in the victim's organism is essential to assess biological damages. This dose distribution can be obtained by physical dosimetric reconstruction methods. The laboratory has developed se...
متن کامل