Cycling of the mechanical ventilator breath.
نویسنده
چکیده
Patient-ventilator interaction is a key element in optimizing mechanical ventilation. The change from inspiration to expiration is a crucial point in the mechanically ventilated breath, and is termed "cycling." Patient-ventilator asynchrony may occur if the flow at which the ventilator cycles to exhalation does not coincide with the termination of neural inspiration. Ideally, the ventilator terminates inspiratory flow in synchrony with the patient's neural timing, but frequently the ventilator terminates inspiration either early or late. Most current mechanical ventilators include adjustable cycling features that, when used in conjunction with waveform graphics, can enhance patient-ventilator synchrony.
منابع مشابه
Monitoring of patient-ventilator interaction at the bedside.
Monitoring of patient-ventilator interactions at the bedside involves evaluation of patient breathing pattern on ventilator settings. One goal of mechanical ventilation is to have ventilator-assisted breathing coincide with patient breathing. The objectives of this goal are to have patient breath initiation result in ventilator triggering without undue patient effort, to match assisted-breath d...
متن کاملInitiation of the Neurally Adjusted Ventilatory Assist Mode in the Neonatal Period in Iran
Abstract: The new neonatal ventilation methods have been developed along with utilization of new technological tools.This device is synchronized with the patient’s respiratory efforts. The ideal synchronized breath needs to be synchronous with initiation, size, and termination of the breath without delay in detecting of initial resiratory effort by device .The synchrony of respiration contribut...
متن کاملClassic therapies revisited Mechanical ventilation : simplifying the terminology Farhad Kapadia
There is presently considerable ambiguity and confusion relating to ventilator terminology. This can be eliminated using a simple approach, visualising mechanical ventilation as an inspiratory pump, and defining trigger, limit, and cycling in this context. The trigger is the signal that starts a breath by opening the inspiratory valve, the limit is the factor which controls the way gas flows in...
متن کاملNovel modes of mechanical ventilation.
The overarching goal of positive pressure mechanical ventilation is to provide adequate gas exchange support while not causing harm. Indeed, positive pressure mechanical ventilators are only support technologies, not therapeutic technologies. As such they cannot be expected to "cure" disease; they can only "buy time" for other therapies (including the patient's own defenses) to work.Conventiona...
متن کاملComparing the effects of rise time and inspiratory cycling criteria on 6 different mechanical ventilators.
BACKGROUND Inspiratory rise time and cycling criteria are important settings in pressure support ventilation. The purpose of this study was to investigate the impact of minimum and maximum rise time and inspiratory cycling criteria settings on 6 new generation ventilators. Our hypothesis was there would be a difference in the exhaled tidal volume, inspiratory time, and peak flow among 6 differe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 56 1 شماره
صفحات -
تاریخ انتشار 2011