Semiautomated microfluorometric instrument and reagent system for monitoring disease-related immunosuppression.
نویسندگان
چکیده
Several common metabolites and drugs in the serum in of patients with inflammatory, infectious, autoimmune, immunodeficient, neoplastic, and toxicant-induced diseases can produce artifactual suppression of the [methyl-3H]-thymidine assay, which is widely used to evaluate lymphocyte responsiveness. We have developed a sensitive, semiautomated, fluorescence-enhancement assay in which true immunosuppressors are measured in the presence of absence of such interfering substances. Peripheral blood lymphocytes are activated with mitogens in standard microtiter culture trays. Changes in lymphocyte DNA content are quantified with a reagent formulation containing mithramycin, the fluorescence of which is enhanced on binding to DNA in the presence of MgCl2. We solubilize cells within the intact microtiter tray by using an automated, inverted "Array Sonicator," and measure fluorescence with an automated, photon-counting fluorometer. With this system, immune response modulation can be accurately assessed in the presence of patients' sera and other complex test substances (e.g., supernates from hybridomas, fermentation vats, viral preparations, and macrophage cultures.
منابع مشابه
Modified semiautomated method for free fatty acids in serum.
Modifications have been made to the reagent system of the semiautomated method for the determination of plasma free fatty acids by Baird et al. (1967), and results are reported of investigations into parameters affecting sensitivity and analytical range.
متن کاملDirect determination of serum chloride with a semiautomated discrete analyzer.
I show how mercuric thiocyanate reagent can be used in assaying serum chloride economically, rapidly, and precisely. I used a semiautomated discrete analyzer with direct concentration read-out capability but the method can easily be applied to many mechanized instruments. Linearity between concentration and color is obtained by adding appropriate amounts of mercuric nitrate to the reagent. As m...
متن کاملA Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia
Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...
متن کاملAutomation of APAAP immunocytochemical technique.
A tissue processing instrument (the Histokinette) was modified by the addition of an electronic timing device which allows an immunocytochemical staining technique (the APAAP method) to be performed as a semiautomated procedure. After incubation with primary monoclonal antibodies (applied by hand) slides (up to 72 in a batch) are placed in racks and cycled through tanks of reagents, comprising ...
متن کاملFactor Analysis of a Novel Scoring-Based Instrument on Forecasting Malaysian Travelers’ Behavioral Preparedness for Travel-Related Infectious Diseases
Introduction: Preparedness for the prevention of travel-related infectious diseases among Malaysian international travelers has yet to be explored. With no such data, health programs to empower travelers on behavioral responses towards travel-related illnesses will be ineffective. The current study aimed to develop and validate a new scoring-based instrument measuring Malaysian...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 28 9 شماره
صفحات -