A new, highly sensitive immunoradiometric thyrotropin (TSH) assay involving solid-phase-coupled monoclonal antibodies (Boots-Celltech Sucrosep IRMA-TSH) has been evaluated in a wide variety of patients with thyroidal and nonthyroidal illnesses and the results compared with those obtained by conventional diagnostic TSH RIAs. The sensitivity of the present assay ranged from 0.036 to 0.1 milli-int. unit/L (mean 0.056). TSH, measurable in serum of each of 128 euthyroid patients, ranged from 0.1 to 6.3 milli-int. units/L (mean 1.7, SD 1.1). Similar concentrations were found in 15 healthy pregnant women. TSH was undetectable in 27 hyperthyroid patients, of whom six were tested with thyroliberin stimulation and failed to respond. The mean TSH concentration measured in 62 seriously ill hospital patients of 2.7 (SD 2.5) milli-int. units/L was significantly higher (p less than 0.05) than in the euthyroid patients. Basal values and peak TSH responses to thyroliberin testing correlated well (r = 0.63, n = 48), irrespective of clinical diagnosis. We conclude that the present assay readily discriminates between euthyroid and hyperthyroid patients and should replace conventional TSH RIAs in diagnostic laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A sensitive immunoradiometric assay for serum thyroid stimulating hormone.

The value as a thyroid function test of a new, rapid, and highly sensitive immunoradiometric assay for thyroid stimulating hormone (TSH) was assessed in 188 consecutive new patients with suspected hyperthyroidism. The diagnosis was made on clinical grounds and on the basis of serum total triiodothyronine and thyroxine concentrations and the response of TSH to thyrotrophin releasing hormone (TRH...

متن کامل

Immunoradiometric assay of thyrotropin as a "first-line" thyroid-function test in the routine laboratory.

We compared the utility of a sensitive immunoradiometric assay for serum thyrotropin as a "first-line" thyroid-function test with a strategy based on first measuring total thyroxin in serum. The immunoradiometric assay appears to distinguish primary hypothyroidism and hyperthyroidism from euthyroidism in "new" patients. The role of this test in monitoring antithyroid treatment or thyroxin-repla...

متن کامل

Bernutz, Hörn, König and Pickardt: Sensitive assays for thyrotropin in the diagnosis of thyroid disorders

Using two new immunoradiometric assays for thyrotropin, we measured thyrotropin levels in serum of patients suffering from various clinically and biochemically diagnosed thyroid disorders, and in healthy controls. A thyroliberin Stimulation test was performed in all patients and controls. Thyrotropin levels were measured using a solid phase IRMA in 339 patients and a coated tube sandwich assay ...

متن کامل

Clinical value of immunoradiometric assay of thyrotropin for patients with nonthyroidal illness and taking various drugs.

Using a two-site immunoradiometric assay, we measured concentrations of thyrotropin (TSH) in serum of 134 clinically euthyroid subjects, 93 patients with nonthyroidal illness, and 80 patients who were being treated with various drugs. Abnormal concentrations of TSH, free thyroxin, and free triiodothyronine, respectively, were recorded in serum of three (3.2%), 19 (20.4%), and 37 (39.8%) of the ...

متن کامل

Serum thyrotropin as measured with a one-step monoclonal-antibody radioimmunometric assay compared with two commercial radioimmunoassay kits.

We compared results obtained with a commercial immunoradiometric assay kit for human thyrotropin in which monoclonal antibodies are used (Tandem -R TSH (ONE STEP) ImmunoRadioMetricAssay; Hybritech Inc.) with those obtained with two commercial radioimmunoassay methods: GAMMA-DAB [125I]HS-hTSH RIA (Clinical Assays) and Thyro-SHure TSH Diagnostic Kit (Nuclear Medical Laboratories). The correlation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 32 3  شماره 

صفحات  -

تاریخ انتشار 1986