Measured transverse‐axis dosimetric parameters of the model STM1251 I125 interstitial source

نویسندگان

  • Z. Li
  • J. F. Williamson
چکیده

The recent popularity of permanent implants for treatment of prostate cancer has created a large demand for low energy seed sources. Vendors have introduced new source designs to meet this demand. The AAPM has recommended that all low energy interstitial brachytherapy seed sources be subjected to independent dosimetric evaluations, preferably using experimental measurements as well as Monte Carlo calculations. This work presents the results of Thermo-Luminescence Dosimeter (TLD) measurements of dosimetric parameters on the transverse axis of a new 125I seed source, the Source Tech Medical STM1251 125I seed. Experimental measurements were performed in a Solid Water phantom, with the results corrected to values for liquid water using Monte Carlo calculated correction factors. The parameters measured include the dose rate constant and values of the radial dose function at distances of 0.5 cm through 5 cm. The measured dose rate constant in liquid water for the STM1251 125I seed was 1.039 cGy/U-hr. Measured radial dose function values agreed with Monte Carlo calculated ones to within 10%. These measurements therefore confirm the modeling and simulation of Monte Carlo calculations for this 125I source design, within the statistical uncertainties of the calculation and measurement techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source

Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...

متن کامل

Determination of Dosimetric characteristics of a New 192Ir-PDR Brachytherapy Source According to AAPM TG- 43 Protocol using Monte Carlo simulation technique

Introduction: 192Ir is one of the important sources frequently used in brachytherapy. Up to now, a lot of commercial models of this source have been made which Ir-192 has been recently added to them. The aim of the present study is to determine the dosimetric parameters of this new source model based on the recommendations of TG-43(U1) protocol using Monte Carlo simulation tech...

متن کامل

Evaluating the doismetric characteristics of some beta- emitter radionuclides for skin lesions irradiation

Introduction: The dosimetric characteristics of patch sources including 32P, 90Y, 188Re and 166Ho, which are employed for radionuclide skin therapy, have been evaluated in current study Materials and Methods: The patch sources understudy were modeled by MCNPX Monte Carlo code and corresponding depth dose distribution, transverse dose profile and isodose curves...

متن کامل

Estimation of dosimetric parameters of I-125 brachytherapy source model 6711 using GATE8.1 code

Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...

متن کامل

A Monte Carlo evaluation of the dosimetric characteristics of the EchoSeedTM

Purpose: Recently a new design of a 125 I brachytherapy source was introduced for interstitial seed implants, particularly for prostate seed implants. This new source is the EchoSeedTMModel 6733 125 I brachytherapy source. Due to the differences in source design and manufacturing process from one new source to the next, their dosimetric parameters should be determined according to the American ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2002