Does combining the results from multiple bone sites measured by a new quantitative ultrasound device improve discrimination of hip fracture?

نویسندگان

  • D Hans
  • S K Srivastav
  • C Singal
  • R Barkmann
  • C F Njeh
  • E Kantorovich
  • C C Glüer
  • H K Genant
چکیده

There is a growing interest in the use of quantitative ultrasound (QUS) measurements as an alternative to current radiation-based bone densitometry techniques for the noninvasive assessment of fracture risk. While most of the commercialized ultrasound devices measure only single predefined peripheral skeletal sites, the Omnisense prototype (Sunlight Ltd., Israel) can be used on multiple bones, including the spinous processes. In this study, we examined the ability of speed of sound measured at the calcaneus, distal third and ultradistal radius, proximal third phalanx, metacarpal, capitate, patella, and the posterior process of the thoracic spine to differentiate subjects with hip fractures from normal controls. Seventy-nine postmenopausal Caucasian Israeli women who had sustained an atraumatic fracture of the proximal femur within the last 6 months were recruited from the local population (mean age 80 +/- 8.9 years). As controls, 295 postmenopausal Caucasian Israeli women without osteoporotic fractures were also included (mean age 70 +/- 8.7 years). Discrimination of hip fractures with QUS at all ultrasound sites was highly statistically significant (p < 0.01) (odds ratios [ORs] = 1.4-3.0; area under the ROC curve [AUC] 77-92%), except for the hand metacarpal. Distal radius and calcaneus measurements (ORs = 2.4 and 3.0) were the best discriminators of hip fracture patients from controls. Using a forward selective linear regression model, the discriminator values of combined assessment at two sites were investigated. There was moderate improvement in diagnostic value, but the best combination was the calcaneus with the distal radius, which improved the AUC by 3% and raised both the sensitivity and specificity to 94%. These data demonstrate the encouraging potential of improving discrimination of hip fracture by using multiple-site ultrasonic measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound velocity through the cortex of phalanges, radius, and tibia in normal and osteoporotic postmenopausal women using a new multisite quantitative ultrasound device.

RATIONALE AND OBJECTIVES To assess a new multisite quantitative ultrasound (QUS) device (Sunlight Omnisense 7000 S) suitable for the measurement of speed of sound (SOS) in the phalanges, radius, and tibia. METHODS The study group consisted of 270 healthy Caucasian postmenopausal patients (mean age: 60.0 +/- 7.6 years) and 53 Caucasian postmenopausal patients (mean age: 67.2 +/- 7.4 years) wit...

متن کامل

Lower Bone Mineral Density is Associated with Intertrochanteric Hip Fracture

Background: A better understanding of how bone mineral density and vitamin D levels are associated with femoralneck and intertrochanteric hip fractures may help inform healthcare providers. We asked: 1) In patients age ≥ 55 years,is there a difference in quantitative ultrasound of the heel (QUS) t-score between patients with fractures of the femoralneck and those with fractures of the intertroc...

متن کامل

Hip fracture discrimination study: QUS of the radius and the calcaneum.

As an emerging alternative to current radiation-based bone densitometry techniques, there is a growing interest in the use of quantitative ultrasound (QUS) measurements for the noninvasive assessment of fracture risk in the management of osteoporosis. However, there are also a multiplicity of technologically different QUS devices available on the market and, so far, no study has compared heel a...

متن کامل

Comparison of three bone ultrasounds for the discrimination of subjects with and without osteoporotic fractures among 7562 elderly women.

UNLABELLED Bone ultrasound measures (QUSs) can assess fracture risk in the elderly. We compared three QUSs and their association with nonvertebral fracture history in 7562 Swiss women 70-80 years of age. The association between nonvertebral fracture was higher for heel than phalangeal QUS. INTRODUCTION Because of the high morbidity and mortality associated with osteoporotic fractures, it is e...

متن کامل

Association of New Coronavirus Disease With Fragility Hip and Lower Limb Fractures in Elderly Patients

The novel coronavirus-induced infection (COVID-19) was declared a pandemic by the World Health Organization onMarch 11, 2020. Iran is one of the countries with a high incidence of COVID-19 infection.Data on three patients with fragility hip fracture and COVID-19 infection were collected from one hospital located inBadrud, Isfahan, Iran, from March 1, 2010, to March 30, 2020. A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 1999