Low Body Mass Index but Not Obesity Is Associated With In-Hospital Adverse Events and Mortality Among Implantable Cardioverter-Defibrillator Recipients: Insights From the National Cardiovascular Data Registry
نویسندگان
چکیده
BACKGROUND Implantable cardioverter-defibrillators (ICDs) are placed in patients at risk for sudden cardiac death, but the procedure may cause adverse events. Patient body habitus may be an important factor responsible for ICD implantation complications. We assessed whether underweight or obese compared with normal weight patients, as defined by body mass index (BMI), were at increased risk for adverse events from ICD implantation. METHODS AND RESULTS We studied 83 312 first-time ICD recipients in the National Cardiovascular Data Registry-ICD Registry implanted between April 2010 and June 2011. Using hierarchical multivariable logistic regression adjusted for patient demographic and clinical characteristics, we examined the association of BMI with in-hospital complications, length of hospital stay, and mortality. Underweight (BMI ≤ 18.5 kg/m(2)) patients comprised 1.7% of the cohort (n=1434), whereas obese (BMI ≥ 30 kg/m(2)) patients comprised 40.1% (n=33 339). Overall, a higher proportion of underweight patients experienced complications (normal weight, 2.3%; obese, 2.1%; underweight 5.2%; P<0.0001) and death (normal weight, 0.3%; obese, 0.3%; underweight 0.8%; P=0.026) as a result of ICD implantation. After multivariable adjustment, underweight ICD recipients had a greater odds of complications (odds ratio [OR], 2.15; 95% confidence interval [CI], 1.68 to 2.75; P<0.0001), hospital stay >3 days (OR, 1.62; 95% CI, 1.38 to 1.89; P<0.0001), and in-hospital death (OR, 2.27; 95% CI, 1.21 to 4.27; P=0.011) compared with normal weight patients. Obese patients did not exhibit any meaningful differences in the same outcomes. CONCLUSIONS In a large, real-world population, underweight first-time ICD recipients experienced significantly more periprocedural complications, prolonged hospital stays, and in-hospital death compared with normal weight patients.
منابع مشابه
From the National Cardiovascular Data Registry and Mortality Among Implantable Cardioverter-Defibrillator Recipients: Insights Low Body Mass Index but Not Obesity Is Associated With In-Hospital Adverse Events
Jonathan C. Hsu, Paul D. Varosy, Haikun Bao, Yongfei Wang, Jeptha P. Curtis and From the National Cardiovascular Data Registry and Mortality Among Implantable Cardioverter-Defibrillator Recipients: Insights Low Body Mass Index but Not Obesity Is Associated With In-Hospital Adverse Events Online ISSN: 2047-9980 Greenville Avenue, Dallas, TX 72514 JAHA: Journal of the American Heart Association i...
متن کاملAntithrombotic Therapy and Outcomes After ICD Implantation in Patients With Atrial Fibrillation and Coronary Artery Disease: An Analysis From the National Cardiovascular Data Registry (NCDR)®
BACKGROUND Management of antithrombotic agents after implantable cardioverter defibrillator implantation is challenging, particularly among patients with atrial fibrillation and coronary artery disease. METHODS AND RESULTS Using data from National Cardiovascular Data Registry(®) Implantable Cardioverter Defibrillator Registry(™) linked with Medicare claims data, we identified 25 180 patients ...
متن کاملCardiac perforation from implantable cardioverter-defibrillator lead placement: insights from the national cardiovascular data registry.
BACKGROUND Cardiac perforation is a feared complication of implantable cardioverter-defibrillator (ICD) lead implantation because of the potential for significant morbidity and mortality. Predictors of perforation and the severity of associated adverse events have not been well studied. We sought to identify predictors of cardiac perforation from ICD lead implantation and subsequent outcomes. ...
متن کاملInfluence of age on perioperative complications among patients undergoing implantable cardioverter-defibrillators for primary prevention in the United States.
BACKGROUND- The majority of current implantable cardioverter-defibrillator (ICD) recipients are significantly older than those in the ICD trials. Data on periprocedural complications among the elderly are insufficient. We evaluated the influence of age on perioperative complications among primary prevention ICD recipients in the United States. METHODS AND RESULTS- Using the National Cardiovascu...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...