Functional orientation of the acetabular component in ceramic-on-ceramic total hip arthroplasty and its relevance to squeaking.
نویسندگان
چکیده
AIMS Long-term clinical outcomes for ceramic-on-ceramic (CoC) bearings are encouraging. However, there is a risk of squeaking. Guidelines for the orientation of the acetabular component are defined from static imaging, but the position of the pelvis and thus the acetabular component during activities associated with edge-loading are likely to be very different from those measured when the patient is supine. We assessed the functional orientation of the acetabular component. PATIENTS AND METHODS A total of 18 patients with reproducible squeaking in their CoC hips during deep flexion were investigated with a control group of 36 non-squeaking CoC hips. The two groups were matched for the type of implant, the orientation of the acetabular component when supine, the size of the femoral head, ligament laxity, maximum hip flexion and body mass index. RESULTS The mean functional anteversion of the acetabular component at the point when patients initiated rising from a seated position was significantly less in the squeaking group than in the control group, 8.1° (-10.5° to 36.0°) and 21.1° (-1.9° to 38.4°) respectively (p = 0.002). CONCLUSION The functional orientation of the acetabular component during activities associated with posterior edge-loading are different from those measured when supine due to patient-specific pelvic kinematics. Individuals with a large anterior pelvic tilt during deep flexion might be more susceptible to posterior edge-loading and squeaking as a consequence of a significant decrease in the functional anteversion of the acetabular component. Cite this article: Bone Joint J 2016;98-B:910-16.
منابع مشابه
The squeaking hip: a cause for concern-disagrees.
Total hip arthroplasty with ceramic-on-ceramic bearing surfaces has demonstrated low wear with excellent clinical outcomes. More recently, concerns have surfaced because of the presence of audible squeaking in some ceramic-on-ceramic THA patients. The incidence of this phenomenon has been low and has infrequently required reoperation. The exact etiology of squeaking remains unclear but is likel...
متن کاملInfluence of prosthetic design on squeaking after ceramic-on-ceramic total hip arthroplasty.
Squeaky ceramic-on-ceramic (COC) total hips have received much recent publicity, and implant design may be implicated. We reviewed 270 consecutive COC total hip arthroplasties in 233 patients comparing 4 implant combinations representing 4 manufacturers. A cohort (n = 45) of Stryker Trident acetabular cups paired with Stryker Accolade femoral stems showed a dramatically higher incidence of "pro...
متن کاملCeramic liner fractures presenting as squeaking after primary total hip arthroplasty.
BACKGROUND Squeaking after ceramic-on-ceramic total hip arthroplasty is a relatively uncommon phenomenon. It usually does not require treatment in the absence of pain, mechanical symptoms, and/or relentless squeaking. The purpose of this investigation was to report on four patients who presented with hip pain and squeaking due to fractured ceramic liners after ceramic-on-ceramic total hip arthr...
متن کاملMeta-analysis of the Incidence and Risk Factors for Squeaking after Primary Ceramic-on-ceramic Total Hip Arthroplasty in Asian Patients
PURPOSE The purpose of this study was to assess the squeaking incidence and risk factors after primary ceramic-on-ceramic total hip arthroplasty (THA) in Asian patients using meta-analysis. MATERIALS AND METHODS We performed a meta-analysis of published data on the squeaking incidence and risk factors from 2000 to 2013. Eight studies in Asians were analyzed for both squeaking incidence and ri...
متن کاملThe role of patient factors and implant position in squeaking of ceramic-on-ceramic total hip replacements.
We investigated factors that were thought to be associated with an increased incidence of squeaking of ceramic-on-ceramic total hip replacements. Between June 1997 and December 2008 the three senior authors implanted 2406 primary total hip replacements with a ceramic-on-ceramic bearing surface. The mean follow-up was 10.6 years. The diagnosis was primary osteoarthritis in each case, and no pati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The bone & joint journal
دوره 98-B 7 شماره
صفحات -
تاریخ انتشار 2016