Outer-volume suppression pulses to improve in-vivo 2D MR spectroscopy

نویسندگان

  • R. Kreis
  • D. G. Chong
چکیده

Introduction: Outer volume suppression (OVS) pulses have long been used to improve localization properties of MRS acquisition sequences. For saturation pulses, there is no need to reach 180° and there is no phase requirement for the crushed signal. Therefore, they can be constructed to feature steep profiles and high bandwidth providing reduced chemical shift artifacts (CSA) [1]. These properties have been put to use e.g. to suppress nearby lipid signals or even to define the localized ROI in MRS. The CSA from localization pulses along different directions has also been recognized as the cause for reduced sensitivity for lactate (Lac) in PRESS localization at intermediate TE [2], the reason being that the refocusing pulse in the PRESS sequence is not extending to the A-part of the AX3 spin system in parts of the selected volume, which leads to partial J-refocusing. OVS has been combined with PRESS to improve Lac sensitivity [3]. The same effect is also relevant in 2DJ spectroscopy – or any 2D sequence involving coherence transfer or refocusing by slice selective pulses. Extending a 2DJ sequence with OVS makes spin evolution homogeneous in space. It is shown that this leads to 1) spectra that are closer to those from ideal simulation, normally used in 2D fitting [4] and 2) better cross peak yield, which makes it more sensitive. Methods: All data was acquired on a clinical 3T scanner (Siemens, Trio). The 2D-J sequence was based on the product PRESS sequence using Mao pulses for slice refocusing (~ 1200 Hz bandwidth, exact value depending on coil load). Product outer volume suppression pulses were used to improve ROI definition (over-prescribed PRESS, i.e. PRESS volume enlarged to enable homogeneous refocusing, while ROI dimension is reduced to the prescribed size by OVS pulses). Spectra were acquired from a Lac solution, a metabolite mixture (NAA, Lac, glutamate (Glu), myo-inositol, creatine, creatinine, choline), and in vivo from occipital and parietal brain. Minimum TE 21ms, 2DJ with 32 steps, delta TE of 10-12.5 ms. Data evaluation using jMRUI. Spectral simulation used GAVA [5] with ideal hard pulses. The implemented 2DJ sequence also offers full echo sampling [4] to further improve sensitivity. Results and Discussion: Fig. 1. illustrates the non-ideal J-evolution for the Lac doublet in a plain 2DJ sequence in comparison to the simulation. Eliminating signal from those parts of the ROI where the coupling partner is not subjected to the 180° refocusing pulse leads to more complete evolution, particularly evident at TE’s around 1/J in blue, and increased crosspeak intensity after FFT (red). Fig. 2 shows that the Glu pattern is also affected by the CSA, but differences are more subtle than for Lac because coupling partners have a smaller chemical shift difference. If 2DJ spectra are not fitted, but evaluated as TE-averaged PRESS, addition of OVS pulses guarantees better cancellation of unwanted signals. Main disadvantages of OVS are the potential for incomplete removal of lipid peaks in neighboring tissue – particularly for inhomogeneous B1 –, increased power deposition, and temporal restrictions for water presaturation. Conclusions: Addition of OVS pulses to reduce CSA effects on spin evolution improves cross-peak yield and fitting accuracy for in vivo 2D spectroscopy. References: 1. Tran TK et al MRM 43:23 (2000); 2. Yablonskiy DA et al MRM 39:169 (1998); 3. Edden RAE et al MRM 56:912 (2006); 4. Schulte RF et al NMRB 19:255 & 19:264 (2006); 5. Soher BJ et al JMR 185:291 (2007). Supported by the Swiss National Foundation (320000_120324)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved image quality in GRAPPA-accelerated coronary MRA using an outer volume suppressing 2D-T2-Prep

Background Two-dimensional (2D) spatially selective radiofrequency (RF) pulses may be used to excite a restricted volume of tissue. By incorporating a “pencil beam” 2D pulse into a T2-Prep module, one may create a “2D-T2-Prep” that combines T2-weighting with outer volume suppression. This may be of particular benefit to parallel imaging techniques, where artefacts typically originate from resid...

متن کامل

Segmented 2D-selective RF excitations with weighted averaging and flip angle adaptation for MR spectroscopy of irregularly shaped voxel.

A weighted averaging scheme with flip angle adaptation is presented for segmented 2D-selective RF excitations and applied to single-line segments of a blipped-planar trajectory. Segments covering the central k-space, i.e. those with significant signal contributions, are averaged more often than the (outer) segments with low RF amplitudes and minor signal contributions. For compensation, these o...

متن کامل

Effects of Contrast Agent and Outer Volume Saturation Bands on Water Suppression and Shimming of Hepatic Single-Volume Proton MR Spectroscopy at 3.0T

PURPOSE To determine whether administration of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) and whether placement of the outer volume saturation bands significantly affect shimming and water suppression on hepatic MR spectroscopic prescanning. METHOD Region of interest (ROI) of 2 cm × 2 cm × 2 cm was carefully positioned in the region of the middle portion of the right hepatic lob...

متن کامل

A Cylindrical, Inner Volume Selecting 2D-T2-Prep Improves GRAPPA-Accelerated Image Quality in MRA of the Right Coronary Artery

BACKGROUND Two-dimensional (2D) spatially selective radiofrequency (RF) pulses may be used to excite restricted volumes. By incorporating a "pencil beam" 2D pulse into a T2-Prep, one may create a "2D-T2-Prep" that combines T2-weighting with an intrinsic outer volume suppression. This may particularly benefit parallel imaging techniques, where artefacts typically originate from residual foldover...

متن کامل

Clinical Relevance of Mr Spectroscopy in the Spinal Cord

SUMMARY: MR spectroscopy allows insight into the chemical composition of human tissue noninvasively. Thereby it can help to better characterize pathologic processes affecting the spinal cord andmay provide important clinicalmarkers for differential diagnosis. However, due to technical challenges, it has been rarely applied to the spinal cord. The aim of this review was to summarize the technica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008