Computerized treatment planning in radiation therapy of intact breast: influence of number of CT-cuts.
نویسندگان
چکیده
PURPOSE To compare the accuracy of 2D algorithm with an established 3D algorithm, and to define the number of CT-slices needed for treatment planning of intact breast irradiation. MATERIAL AND METHODS Twenty patients with breast cancer treated with conservative surgery were included in this study, ten of them had right breast cancer and the other 10 patients had cancer of the left breast. For each patient, 3-D calculations (HeLax-TMS) were performed using one CT-slice (central), 3 CT-slices (central, caudal, and cephalic) and full set CT-slices in addition to 2D calculations (Multidata System) on the digitized central cut. All calculations were done using 6MV-photon. RESULTS When using 2D planning with lung correction, a large hot area of 105% was found at the medial and lateral subcutaneous (SC) regions. Comparison of 2D-treatment planning using Multidata System (2D-physics) and 2D-planning using HeLax System (3D-physics) showed that the 2D planning using Multidata System gave a large hot area of 105% compared with HeLax-2D at the subcutaneous region. The central axis dose distributions obtained from 2D and 3D calculations using HeLax system were compared. No differences were found in the two planes (central cut plane) and this was because the two planes were based on the same algorithm. The only difference was that the hot area (110%) was found at the superior or the inferior border of the field. Also, a comparison using the 3D-system for the central slice and the multiple slices showed a difference in calculating the maximum dose to the target of 2.19%, which was Statistically significant (p=0.001). For all left sided patients, the maximum dose to the heart was significantly different from one to full CT-cuts. It was 12.0+/-6.0% when using one CT-cut versus 6.6+/-1.3% when using full CT-cuts (p<0.03). We compared isodose distributions using three and full CT-cuts for both small and large breasts. For the large breast patients, larger differences in isodose distributions were observed in the cephalic and the caudal planes than for small breast patients. CONCLUSION Dose distributions based on a single CT cut through the central axis using 2D or even 3D treatment planning system will lead, quite often, to hot volumes in 76 excess of 105%. For patients whose breast contours vary slowly within the tangential fields, a three-slice CT scan appears to be adequate for clinical decision. However, for patients with large variation of contours within the tangential fields, a full CT scan gives more accurate dose distributions than the three-slice model.
منابع مشابه
Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies
Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...
متن کاملExternal radiotherapy of intact breast: A comparison between 2D (single CT- slice) and 3D (full CT-slices) plans
Background: Tangential irradiation of intact breast is one of the most common procedures performed in any radiotherapy center. This method is performed by using 2D and 3D treatment planning. The aim of this study was to compare 2D with 3D plans in breast conserving radiotherapy. Homogeneity of isodose, and lung received dose were compared. Materials and Methods: Twenty patients with br...
متن کاملThe effect of CT contrast agents on treatment planning and dose calculation in radiation therapy of pelvis cancers
Introduction: Using contrast medium in diagnosis and identifying of an organ from its surrounding tissue is very useful. These contrast mediums alter radiation absorption of studied organs. The aim of this study is to identify the influences of contrast media in treatment planning system of the pelvis. Materials and Methods: Seven patients with pelvis area ...
متن کاملThe Comparison 2D and 3D Treatment Planning in Breast Cancer Radiotherapy with Emphasis on Dose Homogeneity and Lung Dose
Introduction: Breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is usually used for this purpose. This technique is performed using 2D or 3D treatment planning systems. The aim of this study was to compare 2D treatment planning with 3D treatment planning in tangential irradiation in breast conse...
متن کاملThe Effect of Breast Reconstruction Prosthesis on Photon Dose Distribution in Breast Cancer Radiotherapy
Introduction: Siliconeprosthetic implants are commonlyutilizedfor tissue replacement and breast augmentation after mastectomy. On the other hand, some patients require adjuvant radiotherapy in order to preventlocal-regional recurrence and increment ofthe overall survival. In case of recurrence, the radiation oncologist might have to irradiate the prosthesis.The aim of this study was to evaluate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the Egyptian National Cancer Institute
دوره 17 2 شماره
صفحات -
تاریخ انتشار 2005