Membrane Bioreactors for Industrial Wastewater Treatment: Applicability and Selection of Optimal System Configuration

نویسندگان

  • Paul M. Sutton
  • P. M. Sutton
  • Bradford Lane
چکیده

The membrane biological reactor (MBR) configuration has proven to be optimal for treatment of many industrial wastewaters when treatment efficiency is an important consideration. Since installation of the first large, U.S., full scale MBR system for industrial wastewater treatment at the General Motors plant in Mansfield, Ohio in the early 1990s, use of membranes for biomasseffluent separation in biological systems has gained wide appeal both in this country and internationally. Industrial applications have ranged from nitrogen removal from food processing wastewaters to use of the technology to deal with complex organics in wastewaters originating from the production of pharmaceuticals and the manufacture of polymeric membrane materials. Historically, low membrane flux, low permeability, limited membrane life and high membrane costs hindered broad application of the MBR technology. The membrane industry, including independent research and development organizations and system suppliers, invested considerable effort to overcome these limitations over the past decade. The result has been a dramatic increase in the number of new commercial system embodiments of the MBR configuration offered by suppliers and a rapid acceleration in the use of the technology for treatment of industrial wastewaters and other aqueous streams. MBR systems can be categorized according to the location of the membrane component. Until recently, the immersed or internal membrane MBR was typically more cost-effective than the external membrane MBR particularly in the treatment of larger wastewater flows. The technical advantages of the external membrane configuration, and recent significant membrane and system design advances resulting in reductions in operating power costs, have translated to broader application of this configuration. External membrane MBRs have recently been designed to treat wastewater flows as high as 3785 m/day.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removal of lead ions from industrial wastewater: A review of Removal methods

Background and aims: The removing of (potential) toxic heavy metal ions from sewage, especially in industrial and mining waste effluents, has been widely studied in recent years. The aim of present study was to investigate the various methods for lead removal of lead ions from industrial wastewater. Methods: This study was a review research. Data were collected through different databases in va...

متن کامل

Effect of Concentration of Cations on Activated Sludge Properties and Membrane Fouling in Membrane Bioreactors for Wastewater Treatment

This paper presents the results of an investigation on the effects of concentration of cations on activated sludge properties and membrane fouling in submerge membrane bioreactors. The working volume of the experimental setup was two liters. The cellulose acetate membrane was immersed in the bioreactor. The flocculability, settling properties and fouling propensity of activated sludge was measu...

متن کامل

Treatment of Industrial Wastewater by Membrane Bioreactors

Membrane Bioreactors (MBRs) have attracted a significant attention of scientists and engineers in the past two decades. Improvement of membrane technologies coupled with experiences gained from application of membranes in different industrial processes have opened a gamut of opportunities in industrial wastewater treatment. The solidliquid separation that is conventionally carried out in gravit...

متن کامل

Combination of Electrochemical Processes with Membrane Bioreactors for Wastewater Treatment and Fouling Control: A Review

This paper provides a critical review about the integration of electrochemical processes into membrane bioreactors (MBR) in order to understand the influence of these processes on wastewater treatment performance and membrane fouling control. The integration can be realized either in an internal or an external configuration. Electrically enhanced membrane bioreactors or electro membrane bioreac...

متن کامل

on anaerobic – aerobic treatment of industrial and municipal wastewater

Anaerobic–aerobic systems have been remarkably employed in industrial and municipal wastewater treatment for many years. While previously most treatment of wastewaters have been carried out in conventional anaerobic–aerobic treatment plants, in recent years, high rate anaerobic–aerobic bioreactors have been increasingly employed for wastewaters with high chemical oxygen demand (COD). This paper...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006