Flow-Injection Coulometric Detection Based on Ion Transfer and Its Application to the Determination of Chlorpromazine

نویسندگان

  • Joaquín A. Ortuño
  • Antonio Gil
  • Concepción Sánchez-Pedreño
چکیده

A flow-injection coulometric method for the determination of chlorpromazine based on ion transfer into a plasticized poly(vinyl chloride) (PVC) membrane, was developed. The detector used consists of a flow-through cell that incorporates a plasticized poly(vinyl chloride) (PVC) membrane which contains tetrabutylammonium tetraphenylborate as electrolyte. The membrane is located between the flowing solution and an inner aqueous electrolyte solution. Two pairs of electrodes, each pair formed by a reference electrode and a working electrode, are used, one pair in each solution. The potential between the reference electrodes was controlled by a four-electrode potentiostat with ohmic drop compensation. A potential step capable of producing the transfer of the chlorpromazine ion into the membrane was applied during the passage of a wide portion of sample plug through the cell and the corresponding quantity of the electricity was measured. In the selected conditions, a linear relationship was observed between the quantity of electricity and chlorpromazine concentrations over a range of 1x10-6 -1x10-4 M. The detection limit was 2 x 10-7 M. Good repeatability and between-day reproducibility was obtained. No interference was observed on the part of some common ions and pharmaceutical excipients. The method proposed was applied satisfactorily to the determination of chlorpromazine in pharmaceuticals and human urine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FLOW INJECTIOW DETERMINATION OF FLUORIDE BY MURTN-ALUMINUM REAGEM WITH SPECTROEUORIMIETRIC DETECTION

A flow injection system is reported for the determination of fluoride based on its effects on the fluorescence intensity of Al-morin complex at pH 3.0 in ethanol-warn mixture. The effect of important parameters such as excitation and emission wavelengths, pH, reagents concenkations, flow rate of the carrier stream, sample injection volume, time of measurepent and interferences are reported. ...

متن کامل

Application of Ion Mobility Spectrometry for Determination of Morphine in Human Urine

In this study, a rapid, simple and sensitive ion mobility spectrometry (IMS) method with corona discharge as ionization source was described for the morphine determination in human urine. Morphine was extracted and purified from urine samples using solid phase extraction procedure with C18 column. It can offer the clean extracts which no extra peaks were observed in IMS. Under operating experim...

متن کامل

Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine

A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...

متن کامل

Flow Injection Spectrophotometric Determination of Sulphide by Catalytic Reduction of Toluidine Blue

Sulphide was determined spectrophotometrically at 628 nm and pH 6.7 based on its catalytic reduction of toluidine blue in the presence of Se(IV) using a flow injection system. After optimization of the measuring conditions the calibration curve was found linear up to 25 mg/mL and the detection limit was 0.3 mg/mL (30 mL injections). The ...

متن کامل

Rapid and precise coulometric determination and separation of redox inert ions based on electrolysis for ion transfer at the aqueous|organic solution interface.

Flow systems for precise and accurate coulometric determinations of ions that were developed on the basis of electrolytic ion transfer at the aqueous|organic solution (W|O) interface are reviewed. The electrolysis cell in the system is composed of a porous poly(tetrafluoroethylene) tube (1.0 mm inner diameter), a metal wire (0.8 mm diameter) inserted into the tube, O into which the tube is imme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2008