Carotid-femoral pulse wave velocity assessment using novel cuff-based techniques: comparison with tonometric measurement.
نویسندگان
چکیده
BACKGROUND Carotid-femoral pulse wave velocity, a predictor of cardiovascular outcome, is conventionally measured using a tonometer sequentially placed upon the carotid and femoral arteries, gated using an electrocardiogram. Leg cuff detection of the femoral pulse removes the need for signal gating, reduces the time required for a single measurement, but gives different pulse wave velocity values to tonometric analysis. A novel algorithm to correct for the transit time and distance related to the additional femoral segment was applied to the cuff-based approach in this study. METHOD Eighty-eight individuals were recruited across four centres and carotid-femoral pulse wave velocity measured in triplicate using two operators with both a tonometer-based device and a device using an inflated thigh cuff with and without the use of the novel algorithm. Comparison was made by Bland-Altman and regression analysis. RESULTS The unadjusted cuff-based approach gave lower pulse wave velocity values than the tonometer-based approach (6.11 ± 1.27 and 7.02 ± 1.88 m/s, P < 0.001). With application of the algorithm, the cuff-based device gave similar pulse wave velocity values (7.04 ± 1.72 m/s) as the tonometer-based approach (P = 0.86). Analysis of covariance with age showed a difference between the tonometer and cuff-based methods (P < 0.001), with a dependence upon age (P = 0.004). The adjusted cuff-based method gave similar results to the tonometer-based method (P = 0.94), with no dependence upon age (P = 0.46). CONCLUSION This study provided validation of a cuff-based assessment of carotid-femoral pulse wave velocity against the universally accepted tonometric method. Adjusting the cuff-based method for the additional femoral segment measured gives results comparable to the tonometer-based method, for which the majority of population data exist to date.
منابع مشابه
Measurement of pulse wave velocity in children: comparison of volumetric and tonometric sensors, brachial-femoral and carotid-femoral pathways
BACKGROUND Pulse wave velocity (PWV), a measure of arterial stiffness strongly predictive of cardiovascular risk in adults, is usually measured by sequential ECG-referenced carotid and femoral tonometry. A simplified technique, more suitable for use in children, employs simultaneous volumetric recording from a sensor applied over the carotid artery and a cuff applied over the femoral artery or ...
متن کاملDetermination of travel distance for noninvasive measurement of pulse wave velocity: case closed?
Determination of Travel Distance for Noninvasive Measurement of Pulse Wave Velocity: Case Closed? To the Editor: Carotid-femoral pulse wave velocity (cfPWV) is currently considered the gold-standard measurement for arterial stiffness.1 In clinical routine, noninvasive assessment is the only feasible method, whereas, for research purposes, catheter-based invasive determination, as well as MRI, m...
متن کاملComparison of sequentially measured Aloka echo-tracking one-point pulse wave velocity with SphygmoCor carotid-femoral pulse wave velocity.
OBJECTIVES Recently, echo-tracking-derived measures of arterial stiffness have been introduced in clinical practice for the assessment of one-point pulse wave velocity. The purpose of this study was to find a relation between carotid-femoral pulse wave velocity and one-point carotid pulse wave velocity, and to find a value of one-point carotid pulse wave velocity that predicts carotid-femoral p...
متن کاملExpert consensus document on the measurement of aortic stiffness in daily practice using carotid-femoral pulse wave velocity.
Stiffness of elastic arteries like the aorta predicts cardiovascular risk. By directly reflecting arterial stiffness, having the best predictive value for cardiovascular outcome and the ease of its measurement, carotid-femoral pulse wave velocity is now considered the gold standard for arterial stiffness assessment in daily practice. Many different measurement procedures have been proposed. The...
متن کاملValidity and reproducibility of arterial pulse wave velocity measurement using new device with oscillometric technique: A pilot study
BACKGROUND Availability of a range of techniques and devices allow measurement of many variables related to the stiffness of large or medium sized arteries. There is good evidence that, pulse wave velocity is a relatively simple measurement and is a good indicator of changes in arterial properties. The pulse wave velocity calculated from pulse wave recording by other methods like doppler or ton...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of hypertension
دوره 31 11 شماره
صفحات -
تاریخ انتشار 2013