The long-term in vivo behavior of polymethyl methacrylate bone cement in total hip arthroplasty

نویسندگان

  • Hiroyuki Oonishi
  • Haruhiko Akiyama
  • Mitsuru Takemoto
  • Toshiyuki Kawai
  • Koji Yamamoto
  • Takao Yamamuro
  • Hironobu Oonishi
  • Takashi Nakamura
چکیده

BACKGROUND AND PURPOSE The long-term success of cemented total hip arthroplasty (THA) has been well established. Improved outcomes, both radiographically and clinically, have resulted mainly from advances in stem design and improvements in operating techniques. However, there is concern about the durability of bone cement in vivo. We evaluated the physical and chemical properties of CMW1 bone cements retrieved from patients undergoing revision THA. METHODS CMW1 cements were retrieved from 14 patients who underwent acetabular revision because of aseptic loosening. The time in vivo before revision was 7-30 years. The bending properties of the retrieved bone cement were assessed using the three-point bending method. The molecular weight and chemical structure were analyzed by gel permeation chromatography and Fourier-transform infrared spectroscopy. The porosity of the bone cements was evaluated by 3-D microcomputer tomography. RESULTS The bending strength decreased with increasing time in vivo and depended on the density of the bone cement, which we assume to be determined by the porosity. There was no correlation between molecular weight and time in vivo. The infrared spectra were similar in the retrieved cements and in the control CMW1 cements. INTERPRETATION Our results indicate that polymer chain scission and significant hydrolysis do not occur in CMW1 cement after implantation in vivo, even in the long term. CMW1 cement was stable through long-term implantation and functional loading.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polymethylmethacrylate arteriography--A complication of total hip arthroplasty.

We report a complication of contemporary cementing technique in total hip arthroplasty, that is, extensive retrograde filling with polymethylmethacrylate cement of the nutrient artery of the femur.

متن کامل

Ageing and moisture uptake in polymethyl methacrylate (PMMA) bone cements☆

Bone cements are extensively employed in orthopaedics for joint arthroplasty, however implant failure in the form of aseptic loosening is known to occur after long-term use. The exact mechanism causing this is not well understood, however it is thought to arise from a combination of fatigue and chemical degradation resulting from the hostile in vivo environment. In this study, two commercial bo...

متن کامل

Fixation of the Cemented Stem: Clinical Relevance of the Porosity and Thickness of the Cement Mantle

The aim of this review paper is to define the fixation of the cemented stem. Polymethyl methacrylate, otherwise known as "bone cement", has been used in the fixation of hip implants since the early 1960s. Sir John Charnley, the pioneer of modern hip replacement, incorporated the use of cement in the development of low frictional torque hip arthroplasty. In this paper, the concepts of femoral st...

متن کامل

A comparison of distal canal restrictors in primary cemented femoral hip arthroplasty.

A retrospective study evaluated 75 total hip arthroplasties performed over a 4-year period using 4 different cement restrictors. A harvested bone restrictor, polyethylene restrictor (Smith & Nephew, Richards Inc, Memphis, Tenn), Biostop G (Depuy Orthopaedics, Warsaw, Ind), and polymethylmethacrylate (PMMA) (Wright Medical Technology, Arlington, Tex) were compared for the percentage of failures,...

متن کامل

The temperature problem at the bone-acrylic cement interface of the total hip replacement.

Loosening of total joint replacements may be caused in part by thermal necrosis of bone in contact with the high temperature of the polymerizing PMMA acrylic cement. This study reports a method to reduce the temperature of the bone-cement interface below the temperature at which bone results in definite necrosis. By precooling the acetubular component to --84 degrees before insertion into the c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2011