Degree of conversion of dual-cure resins light-cured through glass-fiber posts.

نویسندگان

  • Francesca Cerutti
  • Pier Antonio Acquaviva
  • Massimo Gagliani
  • Marco Ferrari
  • Francesco Mangani
  • Laura E Depero
  • Antonio Cerutti
چکیده

PURPOSE To evaluate the degree of conversion (DC) of dual-curing materials used to lute glass-fiber posts in a simulated root canal polymerized by two different modalities. METHODS Artificial root canals were used to simulate a clinical condition to lute 45 posts by three different dual curing luting cements (Calibra, Multilink Automix and Variolink II). Two light cure modalities were chosen for each luting cement: standard (S group) 400 mW/cm2 for 120 seconds and high-power (H group) 1200 mW/cm2 for 40 seconds. Raman spectra were collected at different positions in the post surface (1, 3, 5 and 7 mm from the coronal-most portion of the post covered in cement) and the percentage degree of conversion was computed. The data were analyzed using ANOVA and post-hoc Student-Neuman-Keuls t-test (P = 0.05). RESULTS The DC of the tested luting composites decreased progressively while increasing the distance from the light tip. Regardless of the polymerization modality (H or S) applied. Conversely, the curing modality significantly influenced the DC of the tested materials, evidencing different responses to the same energy density: Calibra seemed to be less dependent on light-curing than the other tested materials, showing a constant behavior. Multilink Automix reached the highest DCs in the S group compared to the H mode. Variolink II showed an interesting drawback in DC at 7 mm when cured in the H model. Dual-cure materials show adequate monomer conversion but when the distance from the curing light increased, a variable, but significant lowering in conversion rate was observed. In addition, the time and power of curing appeared to be material-dependent and should be calibrated individually.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

پلیمریزاسیون سیمان‌های رزینی دوال کیور کاربردی جهت چسباندن پست‌های فایبری هم‌رنگ دندان

Background and Aim: Insufficient polymerization of resin cements is of considerable clinical importance, because of mechanical deficiencies and biological side effects of uncured resin. Dual cure resin cements are getting popular in luting tooth colored posts and although their curing is claimed to proceed chemically, polymerization efficiency in deep areas of canal is uncertain. The aim of thi...

متن کامل

Polymerization efficiency of glass-ionomer and resin adhesives under molar bands.

OBJECTIVE To determine the degree of cure of a light-cured resin-modified glass ionomer (RMGI) under molar bands compared with a light-cured resin and a dual-cured resin. MATERIALS AND METHODS The 3 cements used were Fuji Ortho LC, Eagle Spectrum resin, and Variolink II dual-cure. Each sample was indirectly light cured for 20 seconds (10 seconds occlusally, 10 seconds cervically) under sectio...

متن کامل

Degree of conversion of resin composite cured by light through a translucent fiber posts

PURPOSE This study evaluated the depth of cure of resin composite cured by light through a translucent fiber post. MATERIALS AND METHODS The opaque plastic tubes in various lengths of 2, 4, 6, 8, 10, 12, 14 mm. were filled with resin composite in which two different translucent fiber posts were inserted into the center and photo-polymerized for 40 seconds. The degree of conversion of the cure...

متن کامل

اثر تابش نور بر روند پلیمریزاسیون سیمان های رزینی

Indirect esthetic restorations have recently gained popularity, and choosing suitable cement is an important concern in this regard. A wide variety of resin cements with different curing models:(chemical, light, dual), have been introduced to the profession, and among them the dual systems are claimed to be able to continue polymerization after stopping the light. In order to study and compare ...

متن کامل

In Vitro Effect of Zirconia and Zirconia Enriched Glass Fiber Composite Posts on Fracture Resistance of Endodontically Treated Teeth

  Objective: Despite the advantages of esthetic posts, lack of studies on their fracture resistance has limited their clinical use. This study aimed to compare the effect of two types of esthetic posts namely zirconia and zirconia enriched glass fiber composite posts on fracture resistance of endodontically treated teeth against compressive forces.   Methods: This in vitro study was conducted o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of dentistry

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2011